Relay output: 

 

 

 

 

 

1 switching contact (CO)  

Switching voltage  

 

 

 

 

max AC 250 V 

Switching current  

 

 

 

 

max 5A 

Switching capacity  

 

 

 

 

max 1250 VA (resistive load) max 120 W at 24 V DC 

Rated operational current Ie   

 

 

AC15  

Ie = 3 A 

Ue = 250 V 

DC13  

Ie = 2 A 

Ue = 24 V 

Ie = 0.2 A  Ue = 125 V 
Ie = 0.1 A  Ue = 250 V 

Recommended initial protection    

 

T 3.15 A (gL) 

Durability of mechanical contacts    

 

3 x10

7

 switching cycles 

Life of electrical contacts  

 

 

 

1 x 10

5

 switching cycles at AC 250 V / 6 A 

 

Test conditions 

 

EN 61010-1 

Rated insulation voltage  

 

 

 

Ui 300 V Pollution degree 2 

Rated withstand surge voltage  

 

 

4000 V 

EMC immunity    

 

 

 

 

EN 61326-1 (industrial environment) 

Interference emission EMC   

 

 

EN 61326-1 CISPR 11 Class B 

Operating cycle   

 

 

 

 

100 % 

Permissible ambient temperature    

 

-20 °C +65 °C (without condensation and icing) 

 

Measuring inputs: 

 

max 30 V, max 3mA 

Connection - current transducer   

 

STWA1 or STWA1H 

current sensor S1 (see Us from STW12V) 

potential-free contacts 

total connection of the listed sensors 
 

Switching point / limit value 

Limit value I (current)    

 

 

 

adjustable via STWA1 AC 0.5 5 A 

Tolerance    

 

 

 

 

 

±20 % 

Current sensor S1 or not adjustable contact 

not adjustable 

Switch off delay    

 

 

 

 

adjustable 1. 60 s 

Reception delay   

 

 

 

 

approx. 0.5 s 

Overload capacity with STWA1  

 

 

max 100A continuous, max 300 A for 10 s 

 

+18V OUT 

17 V ... 21 V 

 

Casing: 

Type V4, distributor mounting 

Mounting depth    

 

 

 

 

55 mm 

Width  

 

 

 

 

 

 

4 TE 

Dimensions (W x H x D) 

 

 

 

70 x 90 x 58 mm 

Cable connection one cable   

 

 

je 1 x 1.5 mm2 

Fine wire with conductor ferrule  

 

 

je 1 x 1.0 mm2  

Tightening torque of fixing screw    

 

0.5 Nm 

Protection deg. enclosure  

 

 

 

IP 30 

Protection deg. snaps   

 

 

 

IP 20 

Fixing  

 

 

 

 

 

 

Snap-on attachment on standard 35 mm rail in accordance  
with EN 60 715 or screw fixing (with additional screw) 

Weight  

ca. 150g, with packaging approx. 175g 

 

Subject to technical changes 
 

 

Содержание STW12V

Страница 1: ...sducers Grid and Plant Protection Operating Manual STW12V updated 2022 09 21 Um For more information and help about this product please scan the QR Code or choose the following link STW12V Operating manual Quick guide Datasheet Connection diagram CAD Data Firmwareupdates FAQ Videos about installation and settings Certificates STW12V 12470 0710 00 Page 1 8 www ziehl de Current Relay 12 inputs in OR...

Страница 2: ...ew 3 4 Display and controls 3 5 Connection diagram 4 6 Important notes 5 7 Assembly 5 8 Detailed description 5 8 1 Connection of current transducer STWA1 H 5 8 2 Current sensor or contact connection only 6 8 3 Mixed operation Transducers sensors and contacts can also operate in mixed mode 6 9 Technical data 6 10 Type V4 8 11 Disposal 8 ...

Страница 3: ...rent transducers type STWA1 H current sensors S1 also DC or potential free contacts If current is detected on at least one input the current sensor turns on or a contact closes the built in relay turns on If the current is turned off in all monitored circuits or if it falls below the set response threshold for detection with STWA1 H the output relay disconnects with the set delay An adjustable res...

Страница 4: ...STW12V 12470 0710 00 Page 4 8 www ziehl de 5 Connection diagram Note When using STWA1H current transducers instead of STWA1 ensure correct wiring of the connections o STWA1H 1 12 o STWA1H ...

Страница 5: ...f a current greater than the set value I flows through at least one of up to 12 monitored wires the relay activates yellow LED is on If the value falls approx 0 3 A below the inrush current yellow LED flashes the relay switches off again after the delay time set with the t adjustment knob has elapsed yellow LED goes out Failure free and safe operation of the equipment requires that it is properly ...

Страница 6: ...urrent I does not work Tipps Response threshold is too high current flow in the wire is too low wires pass through the current transducer STWA1 H several times Response threshold is too low base load current must be extinguished connect a resistor 0 25 W 200 V before the corresponding input of STW to the current transducer STWA1 H 750 Ω resistor increase by a factor 2 330 Ω resistor increase by a ...

Страница 7: ...on and icing Measuring inputs max 30 V max 3mA Connection current transducer STWA1 or STWA1H current sensor S1 see Us from STW12V potential free contacts total connection of the listed sensors Switching point limit value Limit value I current adjustable via STWA1 AC 0 5 5 A Tolerance 20 Current sensor S1 or not adjustable contact not adjustable Switch off delay adjustable 1 60 s Reception delay ap...

Страница 8: ...t panel 6 Position downward 7 Snap on wall mount with screws Screw hole Ø 4 2 mm for fixing to the wall with screws Ø 4 2 mm 11 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provisions ZIEHL is registered with the EAR Foundation under WEEE no DE 49 698 543 70 Option 5 7 6 58 48 16 5 4 1 2 3 61 8 45 3 90 116 98 ...

Отзывы: