date / name ) : 06.09.07 WL / Fz/Fu 

Z. Nr.: 12110-0710-01 

Page  6  of  12 

Type: Minipan 300 

ZIEHL industrie-elektronik GmbH + Co KG, Daimlerstr.13, D-74523 Schwäbisch Hall, Tel.: +49 791 504-0, Fax: -56, e-mail: [email protected] 

Examples: 

 

InPU 

ScAL 

InLo 

InHi 

diLo 

diHi 

dP 

Input 0..10 V 
Display 30..100 % 

10 

USEr 

0.00 

10.00 

30 

100 

0000. 

Input 4..20 mA 
Display 0..100 % 

4-20 

USEr 

4.00 

20.00 

100 

0000. 

Input 0..20 mA 
Display 50.0..500.0  

0-20 

USEr 

0.00 

20.00 

500 

5000 

000.0 

Input 10..90 V 
Display 50.0..500.0  

100 

USEr 

10.0 

90.0 

500 

5000 

000.0 

Input 0-60 mV 
Display 0,0..30.0  

300 

USEr 

60 

300 

000.0 

Input 2..5 V 
Display -50.0..100.0  

10 

USEr 

2.00 

5.00 

-500 

1000 

000.0 

 
Confirm and change to next menu with Set. 
 
Delay of Display (recommended at unstable signals) 

Select menu item with Up/Down until display 

ddiS

 and programmed value alternate. 

Change into parametrizing mode with Set and set delay of display with Up/Down.  
Now the measured value will be written into the display every 0,1 ... 2 s.  

Confirm and change to next menu with Set. 
 

 

Fixed Digits (recommended when measured signal is very unstable or changing rapidly) 

Select menu item with Up/Down until 

F

 and the fixed digits blinking are displayed. When no 

fixed digit is programmed, the last 2 digits are dark.  
Set the fixed digits:  

Fi   

  no 

Fi 0 

   last digit fixed  (

0

Fi00

   last digit fixed  (

00

These digits display 0, independent from measured value. 

Confirm and change to next menu with Set. 

 

Code-lock 

Select menu item with Up/Down until display 

Code

 programmed state alternate. 

Here the parameters can be protected by activating the code-lock. After pushing Set, 

Pin

 is 

displayed. Change to 

Pin 504 

with buttons Up/Down (factory setting). After pushing Set the 

code-lock can be activated or de-activated. After pushing Set again, an individual 

Pin 

Can be selected (write down) 
With activated code-lock, all parameters can be seen but not changed any more.  
In case of problems with the code-lock (forgotten

 Pin

), the lock can be switched off and the 

Pin 

can be set back to 

504

,by pushing the button Set/Reset while connecting the device to 

supply voltage until 

Code 

ofF 

is displayed. 

 

 

Содержание MINIPAN 300

Страница 1: ...elektronik GmbH Co KG Daimlerstr 13 D 74523 Schwäbisch Hall Tel 49 791 504 0 Fax 56 e mail info ziehl de Operating Manual Universal Digital panel meter MINIPAN 300 MINIPAN digital panel meters temperature and mains controlling special purpose instruments for customer requirements www ziehl com ...

Страница 2: ...a 11 Housing 12 Application and short description With its 4 digit 14 mm high display Digital Panel meters of MINIPAN 300 series allow the accurate display of different values in the range 1999 9999 Only 3 designs cover the measuring of DC voltage and current AC voltage and current and temperature with Pt 100 sensors RTD The display can be easily programmed by the customer e g input 0 10 V display...

Страница 3: ...ring of current with external shunt max 150 mV 1 A for direct measuring of current or with external transformer Measuring of Temperature Pt 100 RTD Pt 100 in 2 or 3 wire connection Measuring Range 199 9 850 0 C Resolution 0 1 C Display in C or F Display and operating elements 1 Digital display with 4 digits 2 Button Up 3 Button Set Reset 4 Button Down 5 Decimal point behind last digit off display ...

Страница 4: ...ed and leave the plant according to security in perfect condition If in any case the information in the instructions manual is not sufficient please contact our company or the responsible representative Instead of the industrial norms and regulations written in this instructions manual valid for Europe you must observe the valid and relevant regulations of the corresponding country The measuring i...

Страница 5: ...ush short Selection of menu item Change into display mode Function Taste Set Reset Push short Change into parameter setting mode Parameter setting mode Decimal point behind the last digit FLASHES Function buttons Up Down Push short long Adjustment of parameter value slow fast Function button Set Reset Push short Storage of setting and choice of next parameter Change into menu mode after the last p...

Страница 6: ...ry 0 1 2 s Confirm and change to next menu with Set Fixed Digits recommended when measured signal is very unstable or changing rapidly Select menu item with Up Down until F and the fixed digits blinking are displayed When no fixed digit is programmed the last 2 digits are dark Set the fixed digits Fi no Fi 0 last digit fixed 0 Fi00 last digit fixed 00 These digits display 0 independent from measur...

Страница 7: ...into parametrizing mode with Set and select unit C or F Tips After finishing one menu item it is switched automatically to the next one When the right decimal point in the 7 segment display is on the display mode has been left and the menu items can be chosen with up down menu mode When the right decimal point blinks you are in the parameter setting mode and can change the setting with up down Lon...

Страница 8: ... scaling of measuring input and measuring range by the user InLo InLo InLo InLo measuring range Zero InHi InHi InHi InHi measuring range FullScale diLo diLo diLo diLo displayed value at measured signal InLo diHi diHi diHi diHi displayed value at measured signal InHi dP dP dP dP decimal point ddiS ddiS ddiS ddiS delay of display Fi Fi Fi Fi fixed digits CodE CodE CodE CodE code Pin Pin Pin Pin fact...

Страница 9: ... 0 0 00 0 0 0 1 1 1 10 0 0 0 3 3 3 30 0 0 00 0 0 0 0 0 0 0 2 2 2 20 0 0 0 4 4 4 4 2 2 2 20 0 0 0 1 1 1 1 DC 5 5 5 50 0 0 00 0 0 0 5 5 5 50 0 0 0 1 1 1 10 0 0 0 1 1 1 15 5 5 50 0 0 0 1 1 1 1 AC I I I In n n nH H H Hi i i i 1 1 1 19 9 9 99 9 9 99 9 9 9 9 9 9 99 9 9 99 9 9 99 9 9 9 d d d di i i iL L L Lo o o o 1 1 1 19 9 9 99 9 9 99 9 9 9 9 9 9 99 9 9 99 9 9 99 9 9 9 d d d di i i iH H H Hi i i i 1 1 ...

Страница 10: ...parameters can not be changed The pin can be set by the user Pin unknown Make code reset When switching in supply voltage keep pushed button Set for 2 s Display indicates 8888 CodE oFF 8888 release button Set Code oFF Pin 504 Indicated temperature does not correspond to the sensor temperature 1 Is the correct measuring unit selected C or F 2 Check programmed sensor connection 2 or 3 wire line resi...

Страница 11: ...V Measuring range resistance of input 10 00 V 100 kΩ max 50 V overload capacity 50 0 V 1 MΩ max 60 V 500 0 V 3 MΩ max 600 V 1 00 A Shunt 150 mΩ max 2 A Measuring time AC DC 400 ms delay of display ddis Pt 100 Meter 199 9 850 0 C 328 1563 F Sensor connection Pt 100 2 or 3 wire Wire resistance 3 wire max 3 x 50 Ω Measuring time temperature 400 ms delay of display ddis Accuracy Resolution 9999 1999 E...

Страница 12: ...using Dimensions h x w x d mm 36 x 72 x 79 mm Terminals Wire connection one wire 1 x 0 5 1 5 mm2 Stranded with insulated ferrules 1 x 0 14 1 mm2 Attachment Mounting Panel mount panel cut out 33 0 6 x 68 0 7 mm max thickness of panel 8 mm Protection housing IP 30 Protection terminals IP 20 Weight approx 120 g Subject to technical changes Form Dimensions in mm Panel cut out 33 0 6 x 68 0 7 mm 66 79 ...

Отзывы: