10.15
Statistic menu
All statistical data can be called up in the
Statistic
menu. The data remain saved even after the
frequency inverter has been switched off. Reading out the error list and deleting the error memory are
described in the "Error diagnosis" chapter.
Information
Not all parameters are visible when the
Statistic
menu is opened in the basic level.
Parameter
Description
Value range
Factory
setting
visible in
the basic
level
ST_LST
Error list
Cannot be set
-
X
ST_H
Operating hours
Cannot be set
-
X
ST_DRV
Number of trips
Cannot be set
-
X
ST_RES
Number of mains interruptions
Cannot be set
-
X
ST_SRF
Number of travel aborts due to interruption of the controller
enable RF during the travel
Cannot be set
-
X
ST_SCO
Number of trip aborts due to interruption of the contactor mon-
itoring CO (opening of the contactor) during the travel
Cannot be set
-
X
ST_CRL
Delete error memory
Deletes ST_LST, ST_RES and ST_SRF and ST_SCO
Cannot be set
-
APD
Automatic parameter diagnosis, see "Error diagnosis" chapter
On:
Automatic parameter diagnostics are activated
Off:
Automatic parameter diagnostics are deactivated
On
Off
Off
RESET
Deletes parameters, counter levels and error lists, preassigning
parameters with standard values.
RESET77:
preset parametred frequency inverter:
Parameters will be set
with customer speci
fi
c datas
Standard frequency inverter:
Parameters will be set with
standard data
RESET90:
Device reset, parameters remain preserved. ENC_-
OFF stays.
RESET99:
Device reset, parameters deleted and assigned by
the factory settings.
If a value is entered for the encoder offset (ECOFF), it will also
be deleted!
Reset 77
Reset 90
Reset 99
0
X
TD_PWN
Assign password for the travel direction counter.
A number between 0 and 9999 can be used as a password
0 ... 9999
0
TD_PWC
Displays the password in coded form. If you lose the password,
please contact the manufacturer.
nicht einstellbar
21689
TD_PW
Enter password.
0 ... 9999
0 = no password
0
TD_CNT
Initial value of the down counter
0.00 ... 10.00 M
0.00
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
92/204
Содержание ZETADYN 3BF
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204 ...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204 ...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204 ...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204 ...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204 ...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204 ...