13.5.6
Error 3xx
•
Error before trip start
Error no.
Error text
Error cause
M S
301
MOP: Timeout
Error:
No communication between the application processor and the motor
management processor during start due to an error during the update
Remedy:
Perform a software update
●
●
303
MOP: SW-Error
Error:
Software error message in the motor management processor
Remedy:
Perform a software update
●
●
304
MOP: HW-Error
Error:
Hardware error message in the motor management processor
●
●
305
306
ADC calibration??
Error:
Zero point offset in the motor current detection (analogue digital con-
verter) is outside the tolerance
Remedy:
Replace defective shunt module
●
307
Iu Iv Iw > 1.0A
Error:
Defective current measuring the phase U, V or W
Remendy:
Check the connector of the Shunt-Modul
Current sensors are defekt
●
●
310
No abs.enc
Error:
The connected absolute encoder is not detected (when switching on the
inverter no the absolute encoder was not connected)
Remedy:
Check encoder connection
Switch frequency inverter off and then back on
Parameter im Men
ü
"Encoder & BC"
ü
berpr
ü
fen
●
315
EnDat: HW-error
Error:
EnDat encoder delivers error
●
316
EnDat: Resolution
Error:
Con
fi
gured resolution in the EnDat encoder does not match the encoder
resolution
Remedy:
Enter the correct encoder resolution in the "Encoder & BC" menu
●
320
ENC: Error-start
Error:
Con
fi
gured sinusoidal encoder was not detected
Remedy:
Check connection
Check the encoder type; possibly connect a square wave encoder
●
●
321
EnDat: ULP-error
Error:
While starting, an error was read out from the EnDat encoder. Error is
stated as a code:
0: defective encoder power supply
1: no SSI communication
2: Encoder illumination defective
3: defective signal amplitude
4: Positioning error
5: defective sine evaluation
Remedy:
Check the connection, Check the encoder
322
EnDat: Com-Fehler
Error:
During start, malfunction in communication to EnDat encoder; absolute
value could not be read out
Remedy:
Check the encoder,
Check rotary encoder line
Check the encoder con
fi
guration in the "Encoder & BC" menu
324
SSI: Ack-Error
Error:
During start, malfunction in communication to SSI encoder; absolute
value could not be read out
Remedy:
Check the encoder,
Check rotary encoder line
Check the encoder con
fi
guration in the "Encoder & BC" menu
325
SSI: Timeout
Error:
During start, malfunction in communication to SSI encoder; absolute
value could not be read out, encoder does not reply
Remedy:
Check the encoder,
Check rotary encoder line
Check the encoder con
fi
guration in the "Encoder & BC" menu
327
ENC: Read-Error
Error:
During reading out the position of the absolute encoder (position will be
read out repeatedly) different values will be read.
Remedy:
Check the encoder,
Check rotary encoder line
Check encoder connection (e.g. shielding)
Original operating instructions
ZETADYN 3C
Error diagnosis
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
138/204
Содержание ZETADYN 3BF
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204 ...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204 ...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204 ...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204 ...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204 ...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204 ...