5.5.6
Connection diagram
Brake wiring diagram with micro switch
Figure 5-5-6-01
1 Brake release monitoring
2 Brake
3 Shown with currentless brake
Brake wiring diagram with inductive proximity switch
Figure 5-5-6-02
1 Brake release monitoring
2 Brake
3 Minimum strength 2 mA DC
4 Operating voltage range 10 - 30 V DC
5 Shown with currentless brake
5.6
Forced ventilation
ZAtop SM180.24/B, SM180.35/B and SM180.45/B forced ventilation (optional) - the forced ventilation
is optional and can be added afterwards.
ZAtop SM180.46/B forced ventilation (standard) - the elevator machine ZAtop SM180.46/B is always
delivered with forced ventilation.
5.6.1
Technical data
SM180.24/B
SM180.35/B
SM180.45/B
SM180.46/B
Voltage
220 - 240
220 - 240
[V]
Frequency
50 / 60
50 / 60
[Hz]
Power
1 x 20 / 19
2 x 20 / 19
[W]
Current
1 x 0.125 / 0.11
2 x 0.125 / 0.11
[A]
Table 5-6-1
Original operating instructions
ZAtop
–
model series SM180
Electrical installation
A-TBA17_05-GB 2008 Index 003Part.-No. 01015765-GB (EU-BD 845/1 + 845/2)