Figure 5-3-5-01
1 Frequency inverter
2 Motor temperature monitoring
5.3.6
Connection requirements
Figure 5-3-6-01
Connection Standard
Standard connection requirements
1. Loosen both hexagon head screws M6 (1).
2. The cover plate (3) can now be removed towards the
front.
3. Connect the
ZAtop SM180
according to the connec-
tion diagram.
4. Remount the cover plate (3).
5.
Tightening torque M6 - 8.8: 9.5 Nm
Figure 5-3-6-02
with forced ventilation ZAtop SM180.24/B + 180.35/B
Connection requirements with forced ventilation ZA-
top SM180.24/B + 180.35/B
1. Remove both hexagon head screws M6 (1).
2. Remove the hexagon head screw M10 (2).
3. The eye plate (4) and the cover plate (3) can now be
removed upwards.
4. Do not damage the forced ventilation connecting
cable.
5. Connect the
ZAtop SM180
according to the connec-
tion diagram.
6. Re-attach the cover plate (3) and the eye plate (4).
7.
Tightening torque M6 - 8.8: 9.5 Nm
Tightening torque M10 - 8.8: 46 Nm
Figure 5-3-6-03
with forced ventilation ZAtop SM180.45/B + 180.46/B
Connection requirements with forced ventilation ZA-
top SM180.45/B + 180.46/B
1. Loosen both hexagon head screws M6 (1).
2. Remove both hexagon head screws M10 (2).
3. Remove both eye sheets (4) and the forced ventila-
tion (5) towards the front.
4. Remove the cover plate (3) upwards.
5. Do not damage the forced ventilation connecting
cable.
6. Connect the
ZAtop SM180
according to the connec-
tion diagram.
7. Remount the cover plate (3), the forced ventilation (5)
and both eye sheets (4).
8.
Tightening torque M6 - 8.8: 9.5 Nm
Tightening torque M10 - 8.8: 46 Nm
Original operating instructions
ZAtop
–
model series SM180
Electrical installation
A-TBA17_05-GB 2008 Index 003Part.-No. 01015765-GB (EU-BD 845/1 + 845/2)
14/76