background image

1

1

2

3

3

Figure 2

1

Marking 1

2

Marking 2

3

Reference point

Maximum permitted 

ank clearance for simpli

ed measurement

Drive

Gear

Brake drum di-

ameter

in mm

Gear ratio

Number of 

teeth

Worm gear

Number of 

turns

Worm

Maximum permitted

ank clearance S 

in mm

ZAS0

SWG0

220

51:1

51

1

32

ZAS0

SWG0

220

39:1

39

1

25

ZAS0

SWG0

220

49:2

49

2

16

ZAS1

SWG1

220

51:1

51

1

32

ZAS1

SWG1

220

40:1

40

1

25

ZAS1

SWG1

220

33:1

33

1

21

ZAS1

SWG1

220

50:2

50

2

16

ZAS1

SWG1

220

39:2

39

2

12

ZAS1

SWG1

220

27:2

27

2

9

ZAS2

SWG2

260

46:1

46

1

35

ZAS2

SWG2

260

38:1

38

1

29

ZAS2

SWG2

260

28:1

28

1

21

ZAS2

SWG2

260

45:2

45

2

17

ZAS2

SWG2

260

35:2

35

2

13

ZAS2

SWG2

260

27:2

27

2

10

ZAS3

SWG3

280

46:1

46

1

37

ZAS3

SWG3

280

38:1

38

1

31

ZAS3

SWG3

280

28:1

28

1

23

ZAS3

SWG3

280

45:2

45

2

18

ZAS3

SWG3

280

35:2

35

2

14

ZAS3

SWG3

280

27:2

27

2

11

If the limit value is reached when checking using the simpli

ed 

ank clearance measurement, a 

comprehensive 

ank clearance measurement must be performed.

We recommend noting the result of the measurement in the elevator documentation.

Service instructions 

ZAS0, ZAS1, ZAS2, ZAS3

Flank backlash measurement

A-TIA19_07-GB 1936 Index 001

Part.-No. 01013457-GB

7/12

Содержание ZAS Series

Страница 1: ...ZIEHL ABEGG SE Heinz Ziehl Stra e 74653 K nzelsau Tel 49 7940 16 0 drives ziehl abegg de www ziehl abegg de A TIA19_07 GB Article no 01013457 GB Issue 1936 Index 001 Erstellt am 02 09 2019 ZAS0 ZAS1 Z...

Страница 2: ...4 Flank backlash measurement 6 4 1 General information 6 4 2 Simpli ed ank clearance measurement 6 4 2 1 Requirements 6 4 2 2 Procedure 6 4 3 Comprehensive ank backlash measurement 8 4 3 1 Tools requi...

Страница 3: ...le No 01008067 GB A TBA13_04 GB A current hardcopy version of the original operating instruction and this service manual must be available at the drive 2 Safety instructions 2 1 Pictographs Safety ins...

Страница 4: ...going training instruction or on apprenticeship may only work on the elevator machine under the supervision of an experienced person This also applies to personnel in general training Comply with the...

Страница 5: ...cking varnish must be undam aged every year Check the distance between the set ting screw for the micro switch and adjust if necessary Check the vicinity of the clutch for unusual wear articles every...

Страница 6: ...Attention If the ank clearance exceeds the maximum permitted value the elevator machine may no longer be used on safety grounds An inadequate tooth width can lead to breakage 4 2 Simpli ed ank clearan...

Страница 7: ...7 2 27 2 9 ZAS2 SWG2 260 46 1 46 1 35 ZAS2 SWG2 260 38 1 38 1 29 ZAS2 SWG2 260 28 1 28 1 21 ZAS2 SWG2 260 45 2 45 2 17 ZAS2 SWG2 260 35 2 35 2 13 ZAS2 SWG2 260 27 2 27 2 10 ZAS3 SWG3 280 46 1 46 1 37...

Страница 8: ...nd 20 N to 50 N of force until a stop is detected This stop point is the reference for the measurement The traction sheave is then moved in the other direction until it reaches a stop again The measur...

Страница 9: ...D Measurement radius in mm cmeas Measured clearance in mm relative to measurement radius 4 3 5 Table values cmax Maximum permitted ank clearance r Reference radius in mm for the maximum permitted ank...

Страница 10: ...cmeas_1 mm Measured clearance measurement 2 cmeas_2 mm Measured clearance measurement 3 cmeas_3 mm Measured clearance measurement 4 cmeas_4 mm Measured clearance measurement 5 cmeas_5 mm Measured clea...

Страница 11: ...er supply using the main switch secure it against being switched back on and check that there is no voltage Do not activate the manual hand release Inspection goal Identi cation of loose nuts Inspecti...

Страница 12: ...cal changes Customer Service phone 49 7940 16 308 fax 49 7940 16 249 drives service ziehl abegg com Headquarters ZIEHL ABEGG SE Heinz Ziehl Stra e 74653 K nzelsau Germany phone 49 7940 16 0 fax 49 794...

Отзывы: