![ZIEHL-ABEGG ZAdyn4C MRL Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/ziehl-abegg/zadyn4c-mrl/zadyn4c-mrl_technical-information_933551005.webp)
ZETADYN 2
ZAdyn4C
Menu Installation & Motor
Value
Encoder & BC menu
M&E
(Encoder Type)
ENC_TYP
ZETADYN 2
ZAdyn4C
Menu INTERFACES
Value
Encoder & BC menu
GEBER
ENC_INC
enter the existing brake chopper or
brake resistor type
BC_TYP
ZETADYN 2
ZAdyn4C
Menu INTERFACES
Value
Control system menu
Set CONFIG to "00:Free"
CTRL
CTRL
01:RF
f_I01
04:V1
f_I02
05:V2
f_I03
06:V3
f_I04
07:VZ
f_I05
02:RV1-UP
f_I06
03:RV2-DOWN
f_I07
ZE1
f_I08
ZE3
f_XBR2
ZE2
f_XBR3
ST
f_O1
MB_Brake
f_O2
SK_1
f_O3
SK_2
f_O4
SK_3
f_O5
V_G1
V_G1
V_G2
V_G2
V_G3
V_G3
Automatic evacuation
In automatic evacuation one of the special inputs ZE1, ZE2 or ZE3 is occupied by the evacuation type
in ZETADYN 2:
•
EVA. 3*AC
•
EVA.>60VDC
•
EVA. 1*AC
•
UPS
The digital input used for this function in ZAdyn4C must be con
fi
gured to the function "12:PARA2".
ZETADYN 2
ZAdyn4C
Menu INTERFACES
Control system menu
ZE1 or
f_I08 or
12:PARA2
ZE2 or
f_XBR2 or
ZE3
f_XBR3
Technical Information
Ensuring the parameter values of the ZETADYN 2
R-TIA18_02-D-GB 2106
Part.-No. 00163466-D-GB
5/24