Reconnect the leads from the ZETADYN 2 to the ZAdyn4C as described in the following table.
ZETADYN 2
ZAdyn4C
Pin
Mains connection (X1)
Pin
Mains connection (X1)
L1
L1
->
L1
L1
L2
L2
->
L2
L2
L3
L3
->
L3
L3
Motor connection (X3)
Motor connection (X3)
U
U
->
U
U
V
V
->
V
V
W
W
->
W
W
Brake chopper (X2)
Brake chopper (X2)
ZK+
ZK+
->
+DC
+DC
ZK-
ZK-
->
-DC
-DC
Temperature monitoring brake
chopper (X-10)
Temperature monitoring brake
chopper (X-MON)
+24V
+24V
->
5
+24V
BC
BC
->
6
BC
Encoder connection (X-12)
Encoder connection (X-ENC8)
1
PE
->
1
2
+24V
->
2
+24V_E
3
GND
->
3
GND
4
+5V
->
4
+5/8V_E
5
/B
->
5
/B
6
B
->
6
B
7
/A
->
7
/A
8
A
->
8
A
PTC thermistor (X-12)
Motor temperature monitoring (X-
MT)
P1
P1
->
1
P1
P2
P2
->
2
P2
Encoder connection asynchronous
motors (SUB-D 9-pole)
Encoder connection asynchronous
motors (X-ENC15)
9-pin SUB-D female connector
->
15-pin SUB-D female connector (with
SUB-D adapter for converting 9-pin to
15-pin, art. no.: L-GL-004-HX-ZA-
ASM-9-15)
Alternatively, the wires of the line of the 9-pin SUB-D male connector can be individually connected to the
impulse encoder connection of the asynchronous motors (X-ENC8).
Encoder connection asynchronous
motors
Encoder connection asynchronous
motors (X-ENC8)
Track A
->
8
A
Track B
->
6
B
N.C.
->
N.C.
Vcc (+ 5 V)
->
4
+5/8V_E
Technical Information
Electrical installation
R-TIA18_02-D-GB 2106
Part.-No. 00163466-D-GB
18/24