![ZIEHL-ABEGG ZAdyn4C MRL Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/ziehl-abegg/zadyn4c-mrl/zadyn4c-mrl_technical-information_933551020.webp)
X-O connecting lead on ZETADYN 2
X-O connecting lead on ZAdyn4C
7
Start-up
7.1
General
For details of commissioning the ZAdyn4C, refer to the
“
Commissioning
”
chapter in the ZAdyn4C
operating instructions.
If the absolute value encoder cable length is greater than 5 m, the operating voltage of the absolute
value encoder has to be checked.
Operating voltage
Consequence
3.6 - 14 VDC
Absolute value encoder can be used.
4.75 - 5.25 VDC
Use an absolute value encoder with an operating
voltage of 3.6 - 14 VDC.
8
Con
fi
guring the ZAdyn4C
"
Parametrise the ZAdyn4C in accordance with the parameter list in the section "Ensuring the
parameter values of the ZETADYN 2".
"
Check the following parameter settings:
Menu
Parameter
Settings
Brake control
CONFIG
01:ZA_IO
Monitoring
BR
Settings according to the number and function of the brake
monitor contacts used (e.g. 1*NC, 2*NC).
Monitoring
P1/P2
Settings according to the type of temperature monitoring (e.g.
PTC, TC, KTY).
Technical Information
Start-up
R-TIA18_02-D-GB 2106
Part.-No. 00163466-D-GB
20/24