6. Screw the thermostatic switch (3) with a
tightening torque of 3 Nm
into the intended thread (J).
A exceeding of the tightening torque leads to the damage of the thermostat switch.
7. Attach the cable gland M16 x 1,5 (4).
8. Put the wires with the insulating tube (K) of the thermostatic switch out of the terminal box from
the motor and put it into the terminal box of the forced ventilation according the illustration.
9. Attach the cable tie (5) as strain relief at the wires with the insulating tube in the forced
ventilation terminal box. Connect the wires according to the wiring diagramm (see chapter
"Electrical installation - Connection forced ventilation).
10. Attach the terminal box plate (G) and fasten with the four hexagon head screws M6 x 8 - 8.8 (F)
with a screw wrench SW 10.
11. Secure the brake terminal box (A) to the
fi
xing plate using the two screws M4 (B) and the
screwdriver T20.