Figure 7-05
Figure 7-06
9. Dismounting absolute encoder (9), see "Replacement of the absolute encoder A-TIA17_02-..."
10.
Caution:
Due to the great weight of the brake body, we recommend you to secure and change
the brake body by using an eye bolt M12 (10) and appropriate lifting gear.
11. Completely unscrew one of the socket cap screws M16 x 190 (11) with a size 14 socket head
wrench
12. Replace the socket cap screw M16 x 190 (11) with a threaded bolt M16 (12) from the
ZIEHL-ABEGG toolkit, article number 70027450.
Figure 7-07
Figure 7-08
13. Fasten the threaded bolt M16 (12) by hand.
14. Replace the two remaining socket cap screws M16 x 190 (11) in turn with a threaded bolt M16 (12)
from the ZIEHL-ABEGG toolkit, article number 70027450.
15. Fasten the threaded bolts M16 (12) by hand.
Figure 7-09
Figure 7-10
16. Secure the brake body 2 (13) to the eye bolt (10) using suitable lifting gear and remove.
ATTENTION! Weight of brake body approx. 50 kg!
17. Detach the brake rotor 2 (14) from the toothed hub. The brake rotor may only be detached by
hand.
ATTENTION! Do not use screwdrivers to release the brake rotor.
The screwdrivers damage the friction lining. Damaged friction linings may not be re-
fi
tted!
Assembly instructions
–
model series ZAtop
Dismounting the brake
A-TIA21_08-GB 2021/21 Index 001
Part.-No. 01013509-GB
8/20