Data direction
Type
Data packet
(hexadecimal)
Remarks
State Modify
Send
NMT
000 | 02 | 01 01
Change status to "In operation"
Receive
Heartbeat
701 | 01 | 05
device in operation
TX-PDO Remote Request
Send
RTR
181 | 00 | RTR
TXPDO0 Remote Request
Receive
PDO
181 | 08 | C8 00 | 06 00 | B6 01 | 53 01 Read out registers i14, i15, i20, i21
Send
RTR
281 | 00 | RTR
TXPDO1 Remote Request
Receive
PDO
281 | 08 | 01 01 | 04 01 | FD 00 | FF 00 Read out registers I22-I25 e.g.
"0x00FF" means temperature = 25.5
°
C
TX-PDO Timer-Settings
TX-PDO timer settings (not possible in conjunction with the "ECblue Watchdog function")
(If the
“
ECblue Watchdog function
”
is used, the TX-PDO timer for the CANopen module must be set to 0)
Send
SDO
601 | 08 | 2B 00 18 05 | E8 03 00 00
Set timer to TXPDO0 for 1,000ms
(0x03E8)
Receive
SDO
581 | 08 | 60 00 18 05 | E8 03 00 00
Send
SDO
601 | 08 | 2B 01 18 05 | E8 03 00 01
Set timer to TXPDO0 for 1,000ms
(0x03E8)
Receive
SDO
581 | 08 | 60 01 18 05 | E8 03 00 01
TX-PDO Receive
Receive
PDO
181 | 08 | C8 00 | 06 00 | B6 01 | 53 01 Read out registers i14, i15, i20, i21
Receive
PDO
281 | 08 | 01 01 | 04 01 | FD 00 | FF 00 Read out registers I22-I25, "0x00FF"
means temperature = 25.5
°
C
Save con
fi
guration
Send
SDO
601 | 08 | 23 10 10 01 | 73 61 76 65
Save con
fi
guration in Flash memory
Receive
SDO
581 | 08 | 60 10 10 01 | 73 61 76 65
The CANOpen standard
fi
ngerprint is
0x65766173
After subsequent reset
Send
NMT
000 | 02 | 81 01
Reset device
Receive
Emergency
081 | 08 | 00 00 00 00 00 00 00 00
no errors existent
Receive
Heartbeat
701 | 01 | 7F
device ready for operation
Send
NMT
000 | 02 | 01 01
Change status to "In operation"
Receive
Heartbeat
701 | 01 | 05
device in operation
Receive
PDO
181 | 08 | C8 00 | 06 00 | B6 01 | 53 01 Read out registers I14, I15, I20, I21
Receive
PDO
281 | 08 | 01 01 | 04 01 | FD 00 | FF 00 Read out registers I22-I25
Control speed, by RX-PDO
Send
PDO
201 | 08 | 00 00 00 00 00 00 C8 00
Speed to 200 rpm
Value 0x00C8
Send
PDO
201 | 08 | 00 00 00 00 00 00 20 03
Speed to 800 rpm
Value 0x0320
Send
PDO
201 | 08 | 00 00 00 00 00 00 00 00
Speed to 0 rpm
Value 0x0000
Several TX-PDO settings
Send
SDO
601 | 08 | 23 00 18 01 | 81 01 00 80
Deactivate COBID for TXPDO0
Receive
SDO
601 | 08 | 60 00 18 01 | 81 01 00 80
Send
SDO
601 | 08 | 2F 00 1A 00 | 00 00 00 00
Deactivate mapping
Receive
SDO
601 | 08 | 60 00 1A 00 | 00 00 00 00