Chapter 1, INSTALLATION
37
6. Fasten the right-angled air hose to the inlet with the
hose clip. Attach the right-angled exhaust bend to the
exhaust pipe with the pipe holder (attach the pipe
holder to the connection of the right-angled exhaust
bend). Attach the right-angled exhaust bend to the
outlet by sliding the pipe lock into the outlet clip (See
Fig. 12).
Fig. 12
Pipe holder
Pipe lock
7. Installation of an external fuel tank
The installation of an external fuel tank is illustrated in
a diagram (Fig. 1-11). The fact that installation tech-
niques for fuel tanks vary means that it is impossible to
provide a specific installation procedure. However, cer-
tain criteria determine the manner in which the heater
is supplied with fuel. Use the following checklist as a
guideline for the installation of an external tank.
5. Place the heater in the desired location. Attach the
right-angled exhaust bend to the outlet (the top open-
ing) and attach the right-angled air hose to the inlet.
Check that everything is firmly attached (See Fig. 11).
Fig. 11
Outlet
Inlet
Right-angled exhaust bend
Right-angled air hose