![Zibro Eurostove Oslo injection (Type B) Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/zibro/eurostove-oslo-injection-type-b/eurostove-oslo-injection-type-b_service-manual_933190070.webp)
Item
Test Item
Specifications
Remarks.
Check mode
• Indication
7SEG turns on "CL:05" (colon lamp flashes), and performs a countdown every minute.
It uses the right two digits to perform a countdown and displays it as "04, 03, 02, 01".
The temperature lamp will turn off.
Relation between countdown for refueling
When a countdown for refueling is displayed in advance, it has priority. If a countdown
for refueling countdown is inserted while a cleaning function is indicated, it also has
priority. If a cleaning function is executed when countdown indication is terminated by
refueling, the remaining cleaning time is displayed.
• Cancelling a cleaning function
If burning changes to Med.-High burning or less while a cleaning function is displayed,
the cleaning function will be cancelled. In addition, when burning is locked, a 2 hour
count is cleared. If the cleaning function is executed, burning will be locked, and the
cleaning function will be cancelled.
• Ventilation start
If the cleaning function is started, it will be performed in accordance with burning
change safety.
Connecting Power plug while pushing Timer Switch to "ON"position, Check mode starts.
Procedure
1. Connecting Power plug pushing Timer Button to "ON"position.
2. Buzzer, All the lamps light on for 5 sec.
3. It checks Switch contact during 5 sec., it starts Check mode after item 4, if more than
one pulse are entered from all the tact switches. If contact switch will be entered
buzzer will be on for 100ms. If the contact of Tact switch is not entered for 5 sec., it
changes to Normal mode displaying "-- : --" (Bar Display). If any tact switch is
pressed, it counts 5 sec. again. Lamp will be lit until all the switch are confirmed
(except Save button and Extension button).
4. It displays the following value at the first of 4 figures of 7 seg.
"30 : -7" : SRE 156
"32 : -7": SRE 166
"40 : -7": SRE 176
"50 : 13": SRE 250
"72 : 13": SRE 260
It displays time (min.) of starting Check point 1 at second figure. (It displays "--" (Bar
display) at second figure in case of first figure. It displays "7" (13 for SRE 250, SRE
260) of 7 min. as initial value and it can be selected "7" to "5", "6", "8", "9",
"22" ("9", "11", "15", "17", "22" for SRE 250, SRE 260) by Up and Down
Buttons. It does not display time during Check mode.