3.2 TIME CHART
SRE 156
SRE 166
SRE 250
SRE 260
SRE 176
T1
Pre-heat timing 1
40s
50s
60s
T2
Pre-heat timing 2
90s
150s
150s
T3
Pre-heat timing 3
150s
210s
180s
T5
Pre-purge timing
10s
10s
10s
T6
Fan motor delay timing
13s
13s
13s
T7
Flame check at start (Safety timing) Ignition failure
40s
40s
50s
T8
Flame check at initial burning (Initial condition)
150s
150s
150s
T9
Forced Med.-High burning
40s
200s*
150s*
T10 Forced High burning
110s
-
-
T11 Blower motor post-purge
15s
30s
15s
T12 Fan motor post-purge
90s
150s
150s
T13 Burner thermistor read time
20m
20m
20m
T14 Waiting time for timer set
10s
10s
10s
T15 Refueling (Refilling - Out of fuel)
10m
10m
10m
T16 Refueling warning interval
120s
120s
120s
T18 Combustion change
30s
60s
60s
T23 Blower motor lock or low rotation
5s
5s
5s
T24 Fuel pump delay timing
3s
5s
5s
T25 Blower motor delay timing
3s
5s
5s
T26 5 seconds buzzer
5s
5s
5s
T27 Blower motor post-purge 2
90s (max.)
150s (max.)
150s (max.)
or 4s (min.)
or 10s (min.)
or 10s (min.)
T28 Blower motor pre-purge activation timing
5s
5s
5s
T30 Lost flame response timing
less than 3s
less than 3s
less than 3s
T31 Post-heat timing 1
40s
40s (min.)
50s (min.)
T32 Post-heat timing 2
80s
80s (max.)
660s (max.)
T35 Lost flame detection timing
30s
30s
30s
T37 Blower motor post-purge 4
30s
60s
60s
T40 Fuel alarm timing
3s
3s
3s
T41 Forced Med.-High burning
-
20s
-
T44 Pre-heating extension timing
30s
30s
30s
T45 Flame current detection timing
10s
15s
15s
* Forced Med. burning
Sequential Time
s: second, m: minute
-31-