-23-
5. TRANSFORMER
z
The
Transformer
supplies
electric
voltage
necessary for each part, by lowering the power
supply of 230 V.
Any broken wire in the
Transformer disorders the operation of the Heater.
Output Voltage without Overload
Green
↔
Green
Approx. AC 12 V
Yellow
↔
Yellow
Approx. AC 140 V
Blue
↔
Blue
Approx. AC 30 V
White
↔
White
Approx. AC 230 V
6. AIR FLOW REGULATING DAMPER
z
Air flow has been adjusted at the factory before the Heater is shipped. The Air Flow
Regulating Damper has been screw-locked, which adjustment is made for a level of
lower than 800 meters. If the Heater is used at a higher level than 800 meters, the
Damper needs to be adjusted.
z
Insufficient air flow may cause combustion vibrations or soot, while an excessive air flow
may cause to fail combustion.
Model
Level lower than
800m
Higher level
SRE 156
SRE 166
38.5mm (Fully closed)
Fully open
SRE 176
Scale 0 (Fully closed)
Fully open
SRE 250
Scale 2
Fully open
Damper
position
SRE 260
Scale 6
Fully open
SRE 156, 166
SRE 176
SRE 260
SRE 250
High
Altitude
Damper
Position
Normal
Damper
Position