BitStorm 4800 Express Model 4821-A2 Installation Guide

4821-A2-ZN21-30

Содержание 4800 EXPRESS 4800 Express

Страница 1: ...BitStorm 4800 Express Model 4821 A2 Installation Guide March 2006 Document Part Number 4821 A2 ZN21 30 ...

Страница 2: ...er Zhone Technologies reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Zhone Technologies to notify any person of such revision or changes End User License Agreement Zhone and Affiliates License Zhone Technologies Inc and or an affiliate Zhone hereby grants you User either an individual or a single business entity the ...

Страница 3: ...deemed a material breach hereof User may make a reasonable number of copies solely for archival or disaster recovery and subject to the restrictions imposed by copyright law but may not modify or otherwise copy the Software User agrees to reproduce product identification copyright and other proprietary notices of Zhone and Licensors on all copies User s rights are only as expressly stated herein Z...

Страница 4: ...the receptacle is not properly grounded the installation must not continue until a qualified electrician has corrected the problem If a 3 wire grounding type power source is not available consult a qualified electrician to determine another method of grounding the equipment 3 Slots and openings in the cabinet are provided for ventilation To ensure reliable operation of the product and to protect i...

Страница 5: ...ides optical coupling to the telecommunication network Once a Class 1 laser product is installed the equipment is to be considered to be a Class 1 Laser Product Appareil à Laser de Classe 1 The customer is responsible for selecting and installing the laser transciever and for insuring that the Class 1 AEL Allowable Emission Limit per EN IEC 60825 is not exceeded after the laser transponders have b...

Страница 6: ... radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Cor...

Страница 7: ... number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five When the equipment is used in a customer premises environment a Model 6051 POTS Splitter must be used to ensure CS 03 compliance Refer to...

Страница 8: ...8 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...

Страница 9: ...ting Configurations 17 Mounting Brackets 17 Installing the Brackets for Rack Mounting 17 Installing the BitStorm 4800 Express Into a Rack 19 Installing the BitStorm 4800 Express on a Wall 21 Installing the BitStorm 4800 Express on a Shelf or Desktop 23 Chapter 2 Cabling 25 Cabling Overview 25 DSL Ports 26 10 100BaseT Uplink Port 2 27 Management Port 28 Console Port 29 Connecting a Terminal or PC t...

Страница 10: ...BitStorm 4800 Express Startup Procedure 39 Login 39 Management Modes 39 Startup Procedure for Inband Management 40 Startup Procedure for Out of Band Management 40 Using the Web Interface 41 System Users 41 Configuration Management SNMP 42 Chapter A Connectors and Pin Assignments 43 Overview 43 DSL Ports Connectors 44 Port 1 and Port 2 10 100BaseT Connectors 45 Console Port Connector 46 Chapter B E...

Страница 11: ...4800 Express Chapter 3 LEDs Explains the meaning and usage of the front panel LEDs Chapter 4 Configuration Describes the minimal configuration steps required to prepare the BitStorm 4800 Express for remote access using the command line interface and web interface Appendix A Connectors and Pin Assignments Provides pinouts for connectors on the BitStorm 4800 Express Appendix B Equipment List Provide...

Страница 12: ...Storm 4800 Express Model 4821 A2 SNMP Reference Contains the information necessary to use Simple Network Management Protocol SNMP to configure and monitor the BitStorm 4800 Express BitStorm 6051 POTS Splitter Installation Instructions Describes how to install the BitStorm 6051 POTS splitter Hotwire 6210 A2 6211 A2 and 6381 A2 User s Guide Describes the installation and operation of the 6210 ADSL b...

Страница 13: ...are provided The unit also may be managed using a network manager such as the Paradyne GrandVIEW Element Management System EMS BitStorm 4800 Express IP DSLAM models and features are listed in Table 1 BitStorm 4800 Express Models and Features 04 17534 POTS 1 24 PORT1 10 100BT CONSOLE PORT2 10 100BT STATUS ALARM TEST DSL PORTS 1 24 25 47 27 29 31 33 35 37 39 41 43 45 26 48 28 30 32 34 36 38 40 42 44...

Страница 14: ...35 mm ETSI rack ETSI brackets are available from Paradyne See Appendix B Equipment List As many BitStorm 4800 Express units may be mounted in a standard rack as there are 1 75 inch 44 45 mm spaces in the rack so long as adequate cooling is provided Mounted vertically against a wall The standard mounting brackets provided can be fastened to the base of the unit for wall mounting Set on a shelf or d...

Страница 15: ...wire Category 5 or better unshielded twisted pair UTP cable The BitStorm 4800 Express to a network Port 1 10 100BaseT 8 position modular plug and 8 wire Category 5 or better unshielded twisted pair UTP cable A Network Management System NMS over a Local Area Network LAN employing 10BaseT or 100BaseT CONSOLE DB9 plug connector and shielded cable z The other connector depends on the serial port on yo...

Страница 16: ...tStorm 4800 Express is shipped in a cardboard shipping container Carefully remove the unit from its shipping container and check for physical damage If the unit shows signs of shipping damage notify your sales representative Package Contents In addition to this installation guide the BitStorm 4800 Express shipping carton should contain z BitStorm 4800 Express DSLAM z AC Power Cable z Two sets of m...

Страница 17: ...k marked with Paradyne Part Number 868 6282 0020 are shipped with the unit Two brackets suitable for a 21 inch 535 mm rack marked ETSI are available from Paradyne as a separate feature see Appendix B Equipment List Rack mounting brackets may also be used to attach the unit to a wall NOTE In this guide the term rack refers to any rack cabinet frame or bay suitable for mounting telecommunications eq...

Страница 18: ...inch racks or six machine screws for 23 inch racks provided with the mounting brackets in the hardware kit 4 Attach the brackets appropriate to your rack size Tighten all screws firmly 02 17324 23 inch 584 mm EIA and Bay Networks Rack Mount 21 1 inch 535 mm Rack Mount 19 inch 483 mm Rack Mount 23 inch 584 mm Nortel Rack Mount ...

Страница 19: ...4 mounting screws and self retaining nuts for rails with unthreaded screw holes To install the BitStorm 4800 Express into a rack 1 Determine where in the rack you will mount the BitStorm 4800 Express If your rack does not have threaded screw holes slip self retaining nuts onto the rails where the BitStorm 4800 Express will be fastened 2 Place the unit so that the brackets rest against the front of...

Страница 20: ...00BT CONSOLE PORT2 10 100BT PORT3 LINK ACT GigE STATUS ALARM TEST ALARM 1 2 23 DSL PORTS 1 24 1000BT 24 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 POTS 1 24 POTS 1 24 PORT1 10 100BT CONSOLE PORT2 10 100BT STATUS ALARM TEST DSL PORTS 1 24 25 47 27 29 31 33 35 37 39 41 43 45 26 48 28 30 32 34 36 38 40 42 44 46 DSL PORTS 25 48 1 23 3 5 7 9 11 13 15 17 19 21 2 24 4 6 8 10 12 14 16 18 20 22 ...

Страница 21: ...9 mm plywood not drywall To install the BitStorm 4800 Express on a wall 1 Identify the 6 32 x 3 16 inch flat head screws provided in the hardware kit and the brackets suitable for a 23 inch rack Two screws are required for each bracket 2 Orient the unit so that the bottom is facing you and the faceplate is at the top 3 Locate the supplied Right Side mounting bracket and fasten it to the right side...

Страница 22: ...6 25 mm apart Do not completely tighten the screws Leave them so their heads are about 1 4 inch 6 mm from the wall 7 Hang the unit from the wood screws to verify that the screws are properly placed The screws should freely slide into the top of the key slots in the brackets Do not fasten the unit to the wall until after it is completely cabled and tested 04 17528 17 85 in 453 mm ...

Страница 23: ...elf or desktop as a standalone unit or in a stack 1 Locate the rubber feet in the hardware kit provided with the unit 2 Turn the unit upside down on a work surface Squares stamped into the bottom of the unit show the proper positions for the feet 3 Remove the protective sheet from the bottom of each foot then press the foot onto a corner of the bottom of the unit 4 Turn the unit right side up and ...

Страница 24: ...Installation 24 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...

Страница 25: ...800 Express has a large variety of possible cabling configurations This chapter describes all possible connections not all of which are required z DSL Ports on page 26 z 10 100BaseT Uplink Port 2 on page 27 z Management Port on page 28 z Console Port on page 29 z Ground on page 31 z Connecting to Power on page 32 ...

Страница 26: ... 1 24 connector 2 If the connector for your cable has a short captive screw attach the cable to the DSL PORTS 1 24 connector and fasten it to the jack screw with its short captive screw 3 If the connector for your cable has a long captive screw remove the provided jack screw from the threaded hole next to the DSL PORTS 1 24 connector Attach the DSL PORTS 1 24 connector to the unit using the long c...

Страница 27: ...T Uplink Port 2 Port 2 is the uplink for the DSLAM A straight through cable can be used regardless of the destination interface since the port automatically distinguishes between an MDI and an MDIX To use Port 2 as the uplink 1 Connect an 8 position modular cable to Port 2 2 Connect the other end of the cable to the uplink interface such as an Ethernet switch ...

Страница 28: ...een an MDI and an MDIX To use Port 1 as the out of band management port 1 Connect an 8 position modular cable to Port 1 2 If the BitStorm 4800 Express is in a rack fasten the cable to a rail with a cable tie 3 Connect the other end of the cable to your Ethernet switch or a network interface card in a PC 04 17529 Ethernet Switch Port 1 PORT1 10 100BT CONSOLE PORT2 10 100BT STATUS ALARM TEST DSL POR...

Страница 29: ... 1 Configure the terminal or terminal emulation program to use the following parameters Speed 9600 bps Data bits 8 Parity None Flow Control None Stop bits 1 2 Determine and procure the proper Data Terminal Equipment DTE cable type The CONSOLE port requires a DB9 plug connector The other connector depends on the serial port on your terminal or PC 3 Connect the DB9 plug connector to the CONSOLE port...

Страница 30: ...2 Connect the DB9 plug connector to the CONSOLE port socket 3 If the modem will be permanently connected fasten the connector to the Management Module with its captive screws If the BitStorm 4800 Express is in a rack dress the cable to the left and attach it to the rail with a cable tie 4 Connect the other end of the cable to the serial port of your modem 04 17531 TST LINE ALM PWR ETHER NET Serial...

Страница 31: ...mp a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire 2 Remove the screw marked by the ground symbol at the right side of the front panel 3 Fasten the ring terminal to the front panel using the same screw 4 Attach the ground wire to an earth ground 04 17532 To Earth Ground POTS 1 24 DSL PORTS 25 48 ...

Страница 32: ...nnect the BitStorm 4800 Express to a power source 1 Insert the supplied power cord into the power socket on the back of the unit 2 If the BitStorm 4800 Express is in a rack dress the power cord to the left and fasten it to the rail with a cable tie 3 Connect the other end of the power cord to a grounded AC power source 4 Make sure the STATUS LED on the front panel is ON green See Chapter 3 LEDs 02...

Страница 33: ...ink LEDs Activity LEDS DSL Ports LEDs PORT1 10 100BT CONSOLE PORT2 10 100BT STATUS ALARM TEST 25 47 27 29 31 33 35 37 39 41 43 45 26 48 28 30 32 34 36 38 40 42 44 46 1 23 3 5 7 9 11 13 15 17 19 21 2 24 4 6 8 10 12 14 16 18 20 22 POTS 1 24 PORT1 10 100B T CONSO LE PORT2 10 100B T STATUS ALARM TEST DSL PORTS 1 24 25 47 27 29 31 33 35 37 39 41 43 45 26 48 28 30 32 34 36 38 40 42 44 46 DSL PORTS 25 48...

Страница 34: ... Ethernet link present Ethernet Link present Ethernet link is present but port is administratively disabled Activity Green Off On No data is being transferred Data is being transferred STATUS Green Off On No power or the unit has not completed initialization Unit has power and has completed initialization ALARM Amber Off On No Alarms Unit failed self test or the unit has exceeded a safe temperatur...

Страница 35: ...peed Initial configuration is performed using the Command Line Interface CLI The CLI is available from a terminal or PC connected to the CONSOLE port or through the management port Port 1 Additional configuration may be necessary depending on the mode used to manage the BitStorm 4800 Express z Inband z Out of band through Port 1 This can be performed using the CLI SNMP or the web interface For mor...

Страница 36: ...ds Command Function clear Clear the system log configure Enter Configuration mode copy Copy from one file to another date Set the time zone and date format end If user is in Administrator mode shifts to User mode if user is in User mode positions interface at top of menu tree exit Terminate current session firmware Download or apply new firmware paging Enable or disable paging more prompt for this...

Страница 37: ...ay ip_address Minimum Access Level Administrator ip_address Specifies the IP address of the default gateway for the management ports Example PDYN configure management default gateway 137 90 127 1 configure management inband address ip_address subnet_mask Minimum Access Level Administrator ip_address Specifies the management IP address Default is 0 0 0 0 disabled Do not configure inband and out of ...

Страница 38: ...s bootp ip_address subnet_mask Minimum Access Level Administrator bootp Specifies that a BOOTP server will determine the management IP address ip_address Specifies the management IP address The default address is 10 10 10 10 Do not configure inband and out of band management on the same subnet subnet_mask Specifies the subnet mask to be applied to the IP address The default mask is 255 255 255 0 E...

Страница 39: ...orm 4800 Express 1 Connect a PC or terminal to the CONSOLE port See Console Port in Chapter 2 Cabling 2 At the login prompt type admin and press Enter 3 At the password prompt press Enter The default login password is blank 4 At the PDYN prompt type privilege and press Enter 5 At the password prompt press Enter The default privileged password is blank You are now logged on and in privileged mode w...

Страница 40: ...t on the same subnet Startup Procedure for Out of Band Management In out of band management you manage the unit through Port 1 To start up the BitStorm 4800 Express using out of band management 1 To avoid losing your connection when the IP address is changed access the CLI using the CONSOLE port 2 Assign an IP address netmask and next hop router using the configure management command For example P...

Страница 41: ... Password blank Click on OK The web interface screen appears 4 Click on the menu tab appropriate to what you would like to do Configuration To configure the system and interfaces Status To display statistics status and contents of memory System To display system information download firmware back up configurations and modify users Diagnostics To start and stop tests System Users For security reaso...

Страница 42: ...on Apply Keep a record of the new password Configuration Management SNMP SNMP access to the unit is disabled by default The read only community string is public and the read write string is private Community strings network management system addresses and trap manager addresses can be set using the System Management SNMP screen To set SNMP parameters 1 Click on the Configuration menu tab then clic...

Страница 43: ...ctors on page 44 z Port 1 and Port 2 10 100BaseT Connectors on page 45 z Console Port Connector on page 46 Figure 2 BitStorm 4800 Express IP Front Panel 04 17535 PORT1 10 100BT CONSOLE PORT2 10 100BT STATUS ALARM TEST DSL PORTS 1 24 25 47 27 29 31 33 35 37 39 41 43 45 26 48 28 30 32 34 36 38 40 42 44 46 DSL PORTS 25 48 1 23 3 5 7 9 11 13 15 17 19 21 2 24 4 6 8 10 12 14 16 18 20 22 ...

Страница 44: ...onnector is CA21A Table 5 lists the pin assignments for these interfaces Note that Pins 25 and 50 are not used Table 5 DSL Connector Pinouts DSL Port Connector Pins Ring Tip 1 or 25 1 26 2 or 26 2 27 3 or 27 3 28 4 or 28 4 29 5 or 29 5 30 6 or 30 6 31 7 or 31 7 32 8 or 32 8 33 9 or 33 9 34 10 or 34 10 35 11 or 35 11 36 12 or 36 12 37 13 or 37 13 38 14 or 38 14 39 15 or 39 15 40 16 or 40 16 41 17 o...

Страница 45: ...ion Guide 45 Port 1 and Port 2 10 100BaseT Connectors Port 1 and Port 2 are 8 pin unkeyed modular jacks for a 10 100BaseT interface Table 6 Port 1 and Port 2 Pinouts Signal Pin Transmitted Data 1 Transmitted Data 2 Received Data 3 Unused 4 Unused 5 Received Data 6 Unused 7 Unused 8 97 15449 Pin 1 Pin 8 ...

Страница 46: ...Console Port Connector The CONSOLE port connector is a DB9 socket connector that supports an EIA 232 E circuit as shown in Table 7 Table 7 Console Port Connector RS 232 Signal Directio n Pin Ground Out 1 Receive Data Out 2 Send Data In 3 Data Terminal Ready In 4 Ground 5 Ground Out 6 NC 7 Ground Out 8 NC 9 ...

Страница 47: ...ess 24 Port IP DSLAM with North America power cord Includes BitStorm 4800 Express 19 and 23 inch mounting brackets and hardware and Installation Guide 4821 A2 427 BitStorm 4800 Express 48 Port IP DSLAM with North America power cord Includes BitStorm 4800 Express 19 and 23 inch mounting brackets and hardware and Installation Guide 4821 A2 447 Mounting Brackets for ETSI 21 inch 535 mm Rack 4200 F1 0...

Страница 48: ...Equipment List 48 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...

Страница 49: ...gnetic Compatibility EMC Meets the following standards z EN 300 386 2 z EN 55024 z EN 55022 Class A z FCC Part 15 Class A z VCCI Class A Interfaces z DSL PORTS 50 pin RJ21X Telco type connector z CONSOLE DB9 EIA 232 E z Port 1 and Port 2 8 pin modular jack 10 100BaseT Operating Environment Ambient Temperature 0 to 50 C 32 to 122 F Relative Humidity 5 to 95 noncondensing Storage Temperature 40 to 8...

Страница 50: ...mption Model 4821 A2 417 12 Watts Maximum Model 4821 A2 427 26 Watts Maximum Model 4821 A2 447 40 Watts Maximum Weight Model 4821 A2 417 11 2 lbs 5 1 kg Model 4821 A2 427 11 2 lbs 5 1 kg Model 4821 A2 447 10 7 lbs 4 8 kg Table 9 BitStorm 4800 Express Technical Specifications Sheet 2 of 2 Specifications Criteria ...

Страница 51: ...mmand Line Interface CLI 36 commands 36 community strings 42 configuration 35 CLI commands 37 mounting brackets 17 configuring inband management 40 out of band management 40 SNMP parameters 42 connectors 43 DSL ports 44 front panel 43 Management port 45 46 POTS splitter 44 CONSOLE port 29 cabling and settings 29 connecting modem 30 description 15 pinouts 46 contents of shipping carton 16 cooling a...

Страница 52: ...22 self retaining nuts 19 unit into rack 19 unit on wall 21 interfaces 49 J jack screw 26 L LEDs 33 Link LEDs 34 login 39 lug for grounding 31 M management modes 39 Management port cabling 28 connector 45 46 description 15 pin assignments 45 46 management port 28 menu tabs 41 models 13 modem connecting to Console port 30 mounting brackets description 17 mounting configurations 14 17 N network mana...

Страница 53: ...le 20 procedure 19 related documents 12 Return key 36 RJ21X connectors 44 RJ45 pinouts 46 S shelf installation 23 shipping carton 16 site preparation 14 site requirements 14 49 SNMP configuring parameters 42 specifications product 49 stacking 14 startup procedures 39 Status LED 34 synopsis of chapters 11 T technical specifications 49 Telco connectors fastening 26 pinouts 44 terminal cabling and se...

Страница 54: ...54 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...