Configuration
40
BitStorm 4800 Express Model 4821-A2 Installation Guide
4821-A2-ZN21-30
Startup Procedure for Inband Management
With inband management, the BitStorm 4800 Express is managed using the
uplink port.
To start up the BitStorm 4800 Express using inband management:
1
To avoid losing your connection when the IP address is changed, access
the CLI using the CONSOLE port.
2
Assign an IP address, netmask, and next-hop router using the
configure
management
command. For example:
PDYN#
configure management inband address 137.90.127.3
255.255.255.0
PDYN#
configure management default-gateway 137.90.127.1
Do not configure inband and out-of-band management on the same
subnet.
Startup Procedure for Out-of-Band Management
In out-of-band management, you manage the unit through Port 1.
To start up the BitStorm 4800 Express using out-of-band management:
1
To avoid losing your connection when the IP address is changed, access
the CLI using the CONSOLE port.
2
Assign an IP address, netmask, and next-hop router using the
configure
management
command. For example:
PDYN#
configure management out-of-band address 137.90.80.3
255.255.255.0
PDYN#
configure management default-gateway 137.90.80.1
You can now access the web interface by typing into the Location field of
your web browser the IP address assigned to the Port 1. See
Using the
Web Interface on page 41
.
Do not configure inband and out-of-band management on the same
subnet.
3
Configure routers as necessary to route data from the NOC to the
BitStorm 4800 Express.
Содержание 4800 EXPRESS 4800 Express
Страница 8: ...8 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...
Страница 24: ...Installation 24 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...
Страница 48: ...Equipment List 48 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...
Страница 54: ...54 BitStorm 4800 Express Model 4821 A2 Installation Guide 4821 A2 ZN21 30 ...