background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Atrie  

WireSpan 

3000/3000E 

MODEM 

 

User's Manual

 

 

Summary of Contents for WireSpan 3000

Page 1: ...Atrie WireSpan 3000 3000E MODEM User s Manual ...

Page 2: ...WireSpan 3000 3000E USER S MANUAL ...

Page 3: ...rsion 3 ATRIE TECHNOLOGY INC 10th Floor 14 Lane 609 Sec 5 Chung Hsin Rd San Chung City Taipei Hsien Taiwan 241 R O C TEL 886 2 29995155 FAX 886 2 29994960 Web www atrie com tw Mail contact mail atrie com tw C Copyright 2001 ATRIE TECHNOLOGY INC ...

Page 4: ... a g e C o n t a i n 2 1 P a n e l D e s c r i p t i o n 2 1 Ca bling Yo ur W ireSp an 3 000 2 5 CHAPTER 3 GETTING START The Fro nt Panel LCD Co ntro ller 3 1 M e n u T r e e O p e r a t i o n 3 3 The Console Port Operation 3 22 CHAPTER 4 DIAGNOSTIC APPENDIX A SPECIFICATION APPENDIX B DTE INTERFACE APPENDIX C MENU TREE ...

Page 5: ...HTU at either the Central Office HTU C or the Remote Distribution HTU R location consists of two pairs of digital transmitter receiver transceiver each connected by a two wire CSA Carrier Serving Area compatible loop WireSpan 3000 supports data rates of Nx64 Kbps up to 2 048 Mbps The DTE interface supported are EIA RS 530 V 35 RS 449 X 21 DTE interface for data transmission support drop insert fun...

Page 6: ...Interface T 1 E 1 Interface 1 544Mbps or 2 048Mbps 1 544Mbps or 2 048Mbps Figure 1 2 WireSpan 3000E The HDSL technology provides a transport method that enables the transmission of data rates up to 2 320Mb s over long distances of unconditioned voice grade twisted pair wire Although the exact distances achievable are dependent upon the exact data rate required cable conditions and configurations p...

Page 7: ...1 3 specification of the WireSpan 3000 Applications z Voice Pair Gain Systems z T1 E1 Extend z High Speed Digital Modems z Personal Communication Systems PCS z Wireless PBX ...

Page 8: ...ce cable For WireSpan 3000E The package should contain the following items 1 The WireSpan 3000E 2 One power cable 3 One user s manual Please contact your dealer if there are any missing or damaged parts Panel Description Front panel The front panel contains a 2 line 16 character LCD display four keys labeled EXIT ENTER LEFT arrow and RIGHT arrow and eight LEDs as shown in Figure 2 1 You can access...

Page 9: ...3000E Table 2 1 lists the LEDs and describes their function Table 2 1 WireSpan 3000 LED Description LED Name Description PWR Power Lights to indicate that the power is apply to the device L1 HDSL Loop1 Lights to indicate that HDSL loop1 is in sync L2 HDSL Loop2 Lights to indicate that HDSL loop2 is in sync ALM Alarm Lights to indicate the alarm conditions in HDSL TST Test Mode Lights to indicate t...

Page 10: ... each control key Table 2 2 Front Panel Keys Keys Functions EXIT Exit to upper menu or abort execution command ENTER Enter menu or confirm your choice LEFT Select next left menu RIGHT Select next right menu 3 LCD Display The front panel LCD display is a 2 16 alphanumerical display It displays the status and configurations of the WireSpan 3000 Please refer to Chapter 3 for detail operation of the L...

Page 11: ... 2 6 rear panel WireSpan 3000E DC POWER The rear panel of your WireSpan 3000 3000E contains the following connectors z AC AC Power Input auto range from AC 90V to 260V z DC DC Power Input range from DC 36V to 72V z HDSL HDSL Line Interface Please refer to Figure 2 3 for pin definition z E1 E1 Line Interface Include 75 Ohm for Coaxial Cable and 120 Ohm for Twisted Pair Please refer to Figure 2 4 fo...

Page 12: ...eive RING1 for E1 loop 4 Transmit TIP2 for E1 loop 5 Transmit RING2 for E1 loop 7 Ground 8 Ground Figure 2 6 RJ 48 C for E1 Line Interface Cabling Your WireSpan 3000 This section describes how to connect your WireSpan 3000 to 1 A personal computer PC or data terminal equipment 2 HDSL Line 3 E1 equipment 4 DTE Interface Instructions for installing each cable shown in Figure2 5 ...

Page 13: ...er HDSL AC COM DTE RX T1 E1 T1 E 1 TX T1 E 1 HDSL ON OFF Figure 2 9 Connecting WireSpan 3000 AC POWER To DTE To Console To E1 interface To Other HDSL DTE RX T1 E 1 T1 E1 TX T1 E1 HDSL ON OFF DC FG 48V To DC Power 36 72 V Figure 2 10 Connecting WireSpan 3000 DC POWER ...

Page 14: ... to 1 Personal computer PC or data terminal equipment 2 HDSL Line 3 E1 equipment Instructions for installing each cable shown in Figure2 6 To Console To E1 interface To Other HDSL OFF ON RX T1 E1 T1 E1 TX T1 E1 HDSL COM 90 260 V To AC Power AC Figure 2 11 Connecting WireSpan 3000E AC POWER ...

Page 15: ...2 8 To Console To E1 interface To Other HDSL OFF ON RX T1 E1 T1 E1 TX T1 E1 HDSL 36 72 V To DC Power 48V FG DC Figure 2 12 Connecting WireSpan 3000E DC POWER ...

Page 16: ... Most options contain several selectable settings Each of the settings affects various operating characteristics Using the front panel control keys you can easily access the options and settings under each category The following sections describe the major options of the menu tree Please refer to Appendix C for detail structure of the menu tree Main Menu The main menu shows up right after power on...

Page 17: ... end signal attenuation noise margin LOS condition and LOST condition DTE Status Displays the DTE interface status of the WireSpan 3000 The status includes control signal status timeslot status E1 Status Displays the E1 loop status of the WireSpan 3000 3000E The status are Received Loss Of Signal Received Loss Of Frame Alignment Received Alarm Indication Signal Received Yellow Alarm Framing Bit Er...

Page 18: ...iagnostic allows user to do variety of loop back to assist user in isolating network problem Note you must choose E1 Terminal mode when you use DTE Port and don t use E1 port in HTU R side Profile The WireSpan 3000 3000E supports 5 user profiles to save for future use Also provide 10 factory default profiles to load Menu Tree Operation STATUS MENU MAIN C STATUS This Menu shows the loop STATUS of H...

Page 19: ...s the user 5 user profile to save or load also provide the factary setting STATUS MENU MAIN C STATUS Press ENTER key to enter loop status Menu STATUS LOOP STATUS This screen shows the HDSL Loop status press ENTER to show Loop1 Loop2 STATUS HTU STATUS L1 ON L2 OFF ON on Line OFF off Line Press Right key shows the CERR STATUS HDSL CRC ERROR COUNT STATUS SCREEN ...

Page 20: ...HTU STATUS FEBE FEBE Far End Block Error L1 FEBE L2 This screen displays the HDSL Loop1 and Loop2 Far End Block Error count Press Exit key to return to FEBE STATUS screen press Right key to show the Input Signal Level screen INPUT SIGNAL LEVEL DISPLAY SIGNAL LV L1 L2 dB SIGNAL LV Input Signal Level This screen shows the current Input Signal Level of Loop1 Loop2 Press Right Key shows the DC OFFSET ...

Page 21: ...shows the HDSL Loop1 Loop2 FAR END SIGNAL ATTENUATION Press Right key to show the NOISE MARG screen NOISE MARGIN DISPLAY NOISE MARG L1 L2 dB NOISE MARG Norise Margin This screen shows the HDSL Loop1 Loop2 receiving Noise Margin Press Right key to show the LOS COND Display LOS CONDITION DISPLAY LOS COND L1 ON L2 OFF LOS COND LOS Condition LOST CONDITION DISPLAY LOST COND L1 ON L2 OFF LOST COND LOST...

Page 22: ... the DTE interface Press ENTER to show the timeslot status THE DTE TIMESLOT STATUS DISPLAY SCREEN DTE TS TIMESLOT STATUS Press ENTER to show the timeslot status 00 01 02 03 There are 32 timeslots in the DTE interface from 00 to 31 each timeslot with 64 kps band width mark represents enable Press Left or Right key to see other timeslot status E1 STATUS MENU STATUS E1 STATUS In E1 status MENU you ca...

Page 23: ...mark shown beside each alarm if present LOCAL LINE STATUS BPV _ TSHORT _ BPV Bipolar Violation TSHORT Transmit Short There will be mark shown beside each alarm if present FRAMING ERROR AND CRC ERROR COUNTER FERR CERR FERR Framing Error count CERR CRC Error count LOF SEF LOF Loss of Frame count SEF Severely Loss of Frame count LCV FEBE ...

Page 24: ...LE port Put the mark on the E1 or HDSL and press the ENTER key to enter the performance screen HDSL PERFORMANCE MONITOR 15 MINUTES 15M ES CRC 15 MINUTE ERROR SECOND CRC The scecond count of CRC error in each second during last 15 minutes Press ENTER key to enter Loop1 Loop2 performance selecting screen 15M ES L1 L2 Select the desire Loop1 or Loop2 press ENTER to get the performance screen from con...

Page 25: ...performance screen from console port HDSL PERFORMANCE MONITOR 24 HOURS HDSL PERF 24H ES CRC 24H ES CRC 24 HOURS ERROR SECOND CRC Press ENTER key to select the Loop1 or Loop2 performance monitor 24H ES L1 L2 Select the desire Loop1 ot Loop2 to get the performance screen from CONSOLE port HDSL SEVERELY PERFORMANCE MONITOR 24 HOURS HDSL PERF 24H SES CRC 24H SES CRC 24 HOURS SEVERELY ERROR SECOND Pres...

Page 26: ...SEVERELY PERFORMANCE MONITOR 15 MINUTES E1 PERF 15M SES CRC 15M SES CRC 15 MINUTES SEVERELY ERROR SECOND E1 E1 PERFORMANCE MONITOR 24 HOURS E1 PERF 24H ES CRC 24H ES CRC 24 HOURS ERROR SECOND E1 E1 SEVERELY PERFORMANCE MONITOR 24 HOURS E1 PERF 24H SES CRC 24H SES CRC 24 HOURS SEVERELY ERROR SECOND E1 CLEAR ERROR COUNTER STATUS CLS ERR CNTR This screen clears all the error counter ...

Page 27: ...L CONFIGURE DTE This Menu can activate configure the DTE port DTE PORT ACTIVATE SETUP DTE DTE ACT STATE This screen can activate the DTE port All the configuration must activate the DTE port to in effect DTE ACT ON OFF Slect ON to activate the DTE port OFF to inactivate the DTE port CLOCK OUTPUT POLARITY SETUP DTE CLKO POLARITY This screen selects the polarity of the clock output ...

Page 28: ... polarity of data output DATO INV NORM INV Select the Normal or Inverse output of data signal DCD OPTION SETUP DTE DCD OPTION Press ENTER key to select DCD option DCD ON OFF Select the desire option ON or OFF for DCD signal DSR OPTION SETUP DTE DSR OPTION Press ENTER key to select DSR option DSR SETUP DTE DATO POLARITY ...

Page 29: ...ect the desire option ON or OFF for CTS signal DTE INTERFACE SELECT SETUP DTE INF TYPE There are EIA530 or V 35 for Interface selection INF TYPE EIA530 V 35 Use Left or Right key to select interface E1 CONFIGURE MENU CONFIGURE E1 SETUP This screen can configure the E1 parameter Press ENTER to enter E1 Framing setup screen E1 FRAMING SETUP SCREEN ...

Page 30: ...30 CAS CRC or UNFRAME FRAMING PCM31 CCS CRC FRAMING PCM30 CAS FRAMING PCM30 CAS CRC FRAMING UNFRAME E1 INTERFACE SELECT E1 SETUP INTERFACE Select the desire Interface for E1 The WireSpan 3000 provide RJ45 with 120 Ohm or BNC connector with 75 Ohm Press ENTER to select Use the Left or Right key to select then press ENRER to confirm INTERFACE 120 OHM TP ...

Page 31: ...s ENTER key to select Use the Left or Right key to select then press ENTER to confirm HTU TYPE HTU C HTU R E1 RECEIVE LINE INTERFACE UNIT SELECT E1 SETUP RLIU RLIU RECEIVE LINE INTERFACE UNIT RLIU LH SH LH LONG HAUL SH SHORT HAUL According the distance of the two Unit to select LONG HAUL or SHORT HAUL LONG HAUL will modify the distortion wave form to get better performance in long distance communc...

Page 32: ... CODING There are two methods of line coding Press ENTER to select CODING AMI HDB3 Use Left or Right key to select AMI or HDB3 line coding AUXILIARY CONFIGURE MENU CONFIGURE AUX This MENU configure the clock source keylock functions CLOCK SOURCE SELECT AUX CLOCK SOURCE There are HDSL E1 INTERNAL DTE clock sources Use Left or Right key to select desire clock source CLK SRC HDSL ...

Page 33: ... in password before activate the keylock function Use Left or Right key to select keylock ON OFF KEYLOCK ON OFF KEYLOCK PASSWORD SETTING AUX KEYLOCK PW The password contains ten numerical charactors You must enter 10 digit of number If you want to change old password you have to enter old password first then enter the new password PWD NEW PWD OLD ...

Page 34: ...igned in same Timeslot Mapping X 00 01 02 03 Select the desire timesolt and press ENTER to enter asign screen Set to DTE to asign and set to IDL to unasign TS 1 DTE IDL ALL TIMESLOT MAPPING WireSpan 3000 ONLY TS MAPPING ALL TIMESLOT If you want to asign or unasign all the 32 timeslots you can use ALL TIMESLOT function to asign or unasign all the timeslot in the same time ALL TS DTE IDL SYSTEM RESE...

Page 35: ... Chapter 4 Local E1 and HDSL LOOP BACK TEST MODE LLB Press ENTER to activate the test Press ENTER then Left or Right key to TEST MODE DISABLE screen to end test REMOTE E1 and HDSL LOCAL LOOP BACK TEST MODE DLB Press ENTER to activate the test Press ENTER then Left or Right key to TEST MODE DISABLE screen to end test REMOTE HDSL LOOP BACK TEST MODE RLB Press ENTER to activate the test Press ENTER t...

Page 36: ...s can be saved by user for later load LOCAL PROFILE PROFILE LOAD LOAD 1 2 3 4 5 Use Left or Right key to select profile and press ENTER to load SAVE PROFILE PROFILE SAVE There are five profile can be saved SAVE 1 2 3 4 5 Use Left or Right key to select profile and press ENTER to save LOAD DEFAULT PROFILE LOAD DEFAULT ...

Page 37: ... HTU R CAS CRC 120 3 HTU C CAS CRC 75 4 HTU R CAS CRC 75 5 HTU C CAS CRC 120 6 HTU C CRC4 120 7 HTU C UNFRAME 120 8 HTU R CAS CRC 75 9 HTU R CRC4 75 10 HTU R UNFARME 75 The Console Port Operation The rear panel contains a DB 9 console port it allows user to use a VT 100 or ANSI terminal for system configuration diagnostics ...

Page 38: ...ct next right menu ENTER RETURN Refresh console screen and exit to upper menu Table 3 1 the function of each key Table 3 4 lists and describes the parameter of the console port Please adjust familiar Terminal Emulator Software according to the Table 3 4 Parameter Value Speed Baud Rate 115200 Data Bits 8 Parity None Stop Bits 1 Terminal Emulation VT 100 or ANSI Table 3 4 Console Port Setting ...

Page 39: ...l E1 and DTE loop Local Side Data Equipment E1 HDSL The data block will be looped back at the local HDSL end of the WireSpan 3000 3000E to Verify the local circuit E1 and DTE z DLB This test examines transmit and receive circuit of the HTU C and HTU R and the HDSL loop Remoe Side Data Equipment E1 HDSL HDSL E1 Local HDSL Device Remote HDSL Device The data block will go through remote WireSpan 3000...

Page 40: ...nd receive circuit of the HTU C and HTU R and the HDSL loop E1 HDSL HDSL E1 HTU C HTU R The data block will go through local WireSpan 3000 3000E HTU C and loop back at remote HDSL end of the WireSpan 3000 3000E HTU R to verify the local circuit and the HDSL line ...

Page 41: ...8Mbps 32ppm Line Code HDB3 Line Impedance 75 Ohm for Coaxial Cable 120 Ohm for Twisted Pair Frame Format Framed G 704 and Unframed G 703 Connect RJ 48C or BNC DTE Interface V 35 V 36 RS 449 RS 530 X 21 V 11 Cable Connector Connector SCSI CLOCK OPTION Clock Source DTE1 Loop Internal E1 USER INTERFACE Configuration Use LCD Display and Keyboard Control Alarm Use Eight LED and LCD for alarm LED Indica...

Page 42: ...ICAL DIMENSIONS Physical dimensions 257mm in W x 266mm in L x 60mm in H POWER REQUIREMENT Input Voltage 90 260 VAC 47 63 HZ AC POWER 36 72 VDC DC POWER ENVIRONMENT Temperature 0 50 Humidity 0 95 non condensing ...

Page 43: ... 13 31 DCDA 8 DCDA 13 IA 5 7 RxCA V RxCA 17 RxCA 8 SA 6 32 TM 18 8 33 9 34 GND 7 GND B GND 7 GND 19 GND 8 10 TxCB AA TxCB 12 TxCB 23 35 TxC1 15 11 TxCA Y TxCA 15 TxCA 5 36 RxD 3 12 37 RxC 17 13 38 DSR 6 DSR E 14 39 CTS 5 CTS D 15 TM 15 TM K TM 25 40 DCD 8 DCD F 16 41 DTRB 23 DTRB 30 17 DTR 20 DTR H 42 DTRA 20 DTRA 12 18 RTS 4 RTS C 43 TxDB 23 TB 9 19 RL 21 RL BB RLB 21 44 TxDA 5 TA 2 20 LL 18 LL J...

Page 44: ... P S R T C D E H F K X V W U AA Y J BB 3 SCSI M EIA530 F 1 7 3 16 2 14 12 15 9 17 4 19 5 13 11 24 20 23 6 22 8 10 18 21 25 4 SCSI M EIA449 F 1 19 6 24 4 22 5 23 8 26 7 25 9 27 17 35 12 30 11 29 13 31 10 14 18 5 SCSI M X 21 F 1 8 4 11 2 9 6 13 3 10 5 12 CABLE 28AWG Braid and foil shielding 500mm ...

Page 45: ...CLS ERR CNTR CONFIGURE E1 SETUP CONFIGURE AUX DIAGNOSTIC TEST MODE PROFILE LOAD PROFILE SAVE PROFILE LOAD DEFAULT HTU C 2E1 1168 120 OHM HDB3 HDSL FE1 MU 1 0 ROM 1 0 CONFIGURE TS MAPPING C 1 APPENDIX C MENU TREE MAIN MENU STATUS MAIN MENU CONFIGURE MAIN MENU DIAGNOSTIC MAIN MENU PROFILE CONFIGURE SYS RST CONFIGURE DTE for WireSpan 3000 only ...

Page 46: ... Frame Bipolar Violation Transmit Short Framing Error CRC Error Loss Frame Line Code Violation Far End Block Error Severely Loss Frame STATUS PERF MONITOR PERF E1 HDSL E1 PERF 15M ES E1 E1 PERF 15M SES E1 E1 PERF 24H ES E1 E1 PERF 24H SES E1 HDSL PERF 15M ES CRC HDSL PERF 15M SES CRC HDSL PERF 24H ES CRC HDSL PERF 24H SES CRC 15M ES L1 L2 15M SES L1 L2 24H ES L1 L2 24H SES L1 L2 15Min Error Second...

Page 47: ...e Line Interface Unit LH Long Haul SH Short Haul SETUP DTE DTE ACT STATE SETUP DTE CLKO POLARITY SETUP DTE DATO POLARITY SETUP DTE DCD OPTION SETUP DTE DSR OPTION SETUP DTE CTS OPTION SETUP DTE INF TYPE DTE ACT ON OFF CLKO INV NORM INV DATO INV NORM INV DCD ON OFF DSR ON OFF CTS ON OFF INF TYPE EIA530 V 35 CONFIGURE E1 SETUP E1 SETUP IDLE CODE IDL CODE 7F FF E1 SETUP LINE CODING CODING AMI HDB3 IN...

Page 48: ... MODE DLB TEST MODE DISABLE C 4 AUX CLOCK SOURCE AUX KEYLOCK PW AUX SET KEYLOCK CLK SRC HDSL PWD OLD CLK SRC E1 PWD NEW CONFIGURE SYS RST SYS RST YES NO CLK SRC INTERNAL CLK SRC DTE CONFIGURE TS MAPPING X 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 TS MAPPING ALL TIMESLOT TS N DTE IDL CONFIGURE AUX for WireSpan 3000 only for WireSpan 3000 only ...