HIGH SPEED INTERNET MODEM FAMILY

microelectronics

C

ermetek

CH2156
CH2157
CH2158
CH2159
CH2160

-
-
-
-
-

I/O

 Ports Send Email Only.

I/O 

Ports & Temp Sense. Send Email Only.

Send Serial Data to/from Internal RAM. Send Email Only.

Send/Receive Data Internal Cache 4MEG RAM memory

Send/Receive Data.  Streaming Data Format

TECHNICAL AND OPERATIONAL OVERVIEW

The iModem® Family of products are pin for pin compatible with the
CH179X and CH2056 modem products.  Referring to Figure 1, the
CH21XX iModem® Family consists of an industrial grade high speed
modem module and a 

m

P controller with associated  internal logic.

The 

m

P controller and the logic provide all the functions required for

internet communication via standard PSTN telephone lines.  The
iModem® utilizes TCP, IP, PPP, PAP, SMTP and POP3 internet
protocols.

The iModem® requires an external RJ11C jack for the PSTN line
connection.  An optional CCITT V.24 serial interface is required
when host processor control of the iModem® is either required or
desired in the specific application.

The iModem® receives iNet AT® commands from the host
processor or receives an event status flag on the Send Email
Control Pin (Pin #6) and proceeds to dial up the local ISP, log on
to the Internet and authenticate and verify user ID and password,
and either send or receive email depending on the command/
status flag received.  All received emails are presented on the
RS232 interface for possible further host processing and reten-
tion.

The send and receive email function may be aborted at any time
during the email activity by activating the Send Email Control Pin
(Pin #6).  This will cause the iModem® to terminate the email
activity and revert to the idle state.

The CH2158/9 and CH2160 iModem® products contain 32K  of
extended memory and, therefore, can store limited emails for
later re-transmission.  However, to fully utilize the receive email
capability,  the RS232 interface should be operational.

FEATURES

   •

Uses Point-to-Point Protocol (PPP) with Password
Authentication Protocol (PAP) to connect to the Internet.

   •

Uses TCP/IP and Simple Mail Transfer Protocol (SMTP) to
send emails.

   •

On Demand and event driven email transmission and
reception.

   •

Programmable using serial interface or using PSTN.

   •

Remote programming using PSTN.

   •

Supports V.90, V.34bis, V.34, V.32, V.22bis, V.22A/B,
V.23, V.21, Bell 212A and 103.

   •

Supports V.80 Synchronous operation.

   •

Error correcting: V.42 LAMP, MNP 2-4 and MNP10.

   •

Data Compression: V.42bis and MNP5.

   •

MNP10 Data throughout enhancement for cellular
operation.

   •

DTE serial interface with speeds up to 230.4kbps.

   •

Automative baud rate adaptability utilizing speed
sensing, flow control and data buffers.

   •

Send & Receive FAX Class 1, Group 3 supported.

   •

Serial V.24, 5 volt interface.

   •

NVRAM directory and stored profiles.

   •

Standard AT Command structure with extensions.

   •

Cermetek  iNet  AT® Command extensions.

   •

Built-in DAA with 1500 VAC RMS isolation 2122V peak
surge protection.

   •

UL 1950 and CSA C22.2 950 (Third Edition) Listed,
Reference UL File E104957.

   •

FCC Part 68 Approved/DOT CSA CS-03 Part I
Approvable.

   •

Pin for Pin compatible with CH179X and HS Family of
modems.

   •

+5 Volt operation with zero power option.

   •

Small size: 1.35” x 1.97” x 0.61” (nominal).

The iModem®s full range of capabilities and features allows  for three
methods of internet control as briefly described below.

Fully Autonomous On Demand and Event Driven Control.
This is the simplest method of operational control.  Application of a
10ms TTL low going pulse (i.e., V<0.6) to the Send Email Control Pin

Each iModem®  contains a fully functional 56kbps modem along
with the hardware and software needed to provide the internet
capability.

Because of this architecture, the iModem® has the unique ability to
operate as either an internet email transceiver or as simply a high
speed modem.

Additionally, the presence of the modem function allows for remote
access to reprogram or reconfigure the iModem® should the need
arise.

 A  valid ISP account ID and password are required to use the internet
features.  As a convenience to our customers, and to facilitate
operational use of the iModem®, Cermetek provides on an interim
basis a pre-programmed ISP account and password with each
iModem® delivered.

The iModem® Family is pin compatible with Cermetek’s HS Modem
family and is FCC Part 68 approved and Canadian DOT approveable.
The modules are designed for PCB throughhole mounting and are
1.35” x 1.97” x 0.61” in size.

INTRODUCTION

Cermetek’s iModem® Family of Internet products are the industries
first self contained modules providing  a complete PSTN internet
communication solution.  Further, the iModem® can operate
autonomously without the need for host processor intervention.

The iModem® Family offers a variety of internet communication
features ranging from simple on demand or event triggered email
transmission (CH2156) to full send and receive unlimited length email
(CH2160).  Internet communication control of the iModem®  exercised
by using one of the following basic control methods:

  1.

Fully Autonomous or event driven control requiring
no host processor intervention.

  2.

Semiautonomous control, requiring one command to be
issued from the host processor.

  3.

Complete host intervention and supervision.

When choosing an implementation scheme utilizing a host processor,
the host controls the iModem® by issuing Cermetek iNet AT®
Commands which are extensions of the standard Hayes AT command
set.

Summary of Contents for iModem CH2156

Page 1: ... Automative baud rate adaptability utilizing speed sensing flow control and data buffers Send Receive FAX Class 1 Group 3 supported Serial V 24 5 volt interface NVRAM directory and stored profiles Standard AT Command structure with extensions Cermetek iNet AT Command extensions Built in DAA with 1500 VAC RMS isolation 2122V peak surge protection UL 1950 and CSA C22 2 950 Third Edition Listed Refer...

Page 2: ...l flow control and to facilitate transmission and reception of large email files Control of the internet capabilities of the iModem can be either event driven semiautonomous or initiated and controlled by a system level host processor Further the iModem can function as a 56K V 90 modem when not connected to the internet Semiautonomous control is a special case of full Host Supervised Control and r...

Page 3: ...n the iModem is operating in the internet state all iNet AT Command communication between the iModem and the host processor DTE is conducted over the RS232 serial interface at 57 6kbps When the iModem is operating in the modem state communication with the DTE can be at any speed up to and including 230 4kbps The resident Modulator Demodulator supports line equalization and forward error correction...

Page 4: ...ecommended that a 10 mF or greater tantalum capacitor in parallel with a 0 1mF ceramic capacitor be used The user must also provide shielding from nearby sources of EMI such as relays motors and other power supplies The iModem is trained to a selected speed with an AT CR training sequence Thus the DTE to modem serial interface speed can be set independent of the DCE or line carrier connecting spee...

Page 5: ...ES The iModem can be in either the Internet State or the Modem State Because the iModem has the unique ability to operate as either a high speed V 90 Modem or as an internet email transceiver the commands sent on TXD or the status of the Send Email Control Pin determine operation iModem Internet State The iModem can be controlled by providing status flags on the Send Email Control Pin pin 6 or by ...

Page 6: ...nd 5C specifying X4 allows the iModem to utilize the entire range of non extended messages whereas X0 suppresses all but the very basic result codes Most of the result codes allowed under X1 X2 and X3 are considered call progress status codes and in practice are suppressed except for the case of debugging activities It is recommended that the non extended result codes be used in all cases It shoul...

Page 7: ...ND EMAIL CONTROL pin Semi Autonomous and Complete Host Intervention Control This method of control requires all commands to be issued in serial fashion The first example assumes that the pre pro grammed ISP and email address is to be used A common host control application involves using the iModem pre programmed internet configuration profile except for the local access ISP phone number Example In...

Page 8: ... 2000 Cermetek Microelectronics Inc Page 8 Document No 607 0017 Rev B 06 00 Table 3 iModem Family Pin Descriptions ...

Page 9: ...ss to send and receive emails The required information can be modified by including it on the appropriate iNet AT Command line at the time the commands are issued from the host processor Commands can be issued to the iModem using any number of commercially available terminal emulation programs such as PROCOM or HYPER TERMINAL As an added service to our customers each iModem is shipped from the fac...

Page 10: ...C E N N O C X X X X X 2 7 1 0 0 0 6 4 T C E N N O C X X X X X 3 7 1 0 0 0 8 4 T C E N N O C X X X X X 4 7 1 0 0 0 0 5 T C E N N O C X X X X X 5 7 1 0 0 0 2 5 T C E N N O C X X X X X 6 7 1 0 0 0 4 5 T C E N N O C X X X X X 7 7 1 0 0 0 6 5 T C E N N O C X X X X X 8 7 1 0 0 0 6 5 T C E N N O C X X X X X 9 7 1 0 0 4 0 3 2 T C E N N O C X X X X X e s r e T r o t r o h S r o e s o b r e V g n o L 0 1 2 ...

Page 11: ...party lines service is subject to state tariffs Changes in Attestation Procedure for Plugs and Jacks Name of applicant attests that the network interface plugs or jacks used on this equipment comply with and will continue to comply with the mechanical requirements specified in Part 68 Sub part F specifically the dimensions tolerances and metallic plating requirements The compliance of these connec...

Page 12: ...er n Sn v Set default S Register to value v V0 Report short form terse result codes V1 Report long form verbose result codes W0 Report DTE speed in EC model W1 Report line speed EC protocol and DTE speed W2 Report DCE speed in EC mode COMMAND FUNCTION COMMAND FUNCTION X0 Report basic call progress result codes i e OK CONNECT RING NO CARRIER also for busy if enabled and dial tone not detected NO AN...

Page 13: ...nous mode P0 Set 10 pps pulse dial with 39 61 make break P1 Set 10 pps pulse dial with 33 67 make break P2 Set 20 pps pulse dial with 39 61 make break P3 Set 20 pps pulse dial with 33 67 make break Q0 Select direct asynchronous mode Q5 Modem negotiates an error corrected link Q6 Select asynchronous operation in normal mode T0 Terminate any test in progress T1 Initiate local analog loopback T2 Retu...

Page 14: ...Status T 0 S17 Reserved S18 Test Timer 0 255 seconds 0 S21 V 24 General Bit Mapped Options Status 52 34h S22 Speaker Results Bit Mapped Options Status 117 75h S23 General Bit Mapped Options Status 62 3Dh S24 Reserved S25 Delay to DTR Off 0 255 seconds or 0 01 second 5 S26 RTS to CTS Delay 0 255 0 01second 1 S27 General Bit Mapped Options Status 73 49h S28 General Bit Mapped Options Status 0 S30 Di...

Page 15: ... answer disabled Command echo ON All result codes enabled except REL codes Wait for dial tone before dialing 2 seconds Dials with touch tone T Detects busy signal ATX4 Full word result codes non extended Pulse dial make break ratio 39 61 10 pps Test timer set to 0 seconds test modes disabled Inactivity timer set to 0 minutes CTS always active DSR is ignored DCD is ignored RTS to CTS delay 01 secon...

Page 16: ... 2000 Cermetek Microelectronics Inc Page 16 Document No 607 0017 Rev B 06 00 Figure 7 PSTN Line Interface for all iNet Appliance Products ...

Page 17: ...e L t u p n I 0 0 1 A u I H O _ _ _ _ T S R t n e r r u C t u p n I 0 0 5 A u CP _ _ _ _ _ _ d a o L e v i t i c a p a C D X T S T R R T D S T R d a o L e v i t i c a p a C 0 1 8 F p F p r e t e m a r a P r e t e m a r a P r e t e m a r a P r e t e m a r a P r e t e m a r a P m u m i n i M m u m i n i M m u m i n i M m u m i n i M m u m i n i M l a c i p y T l a c i p y T l a c i p y T l a c i p y...

Page 18: ...ure Sense Pin Email Send Control Pin 0 C to 70 C Send port status emails Full Function V 90 FCC Part 68 Approved UL1950 listed modem CH2158 2 Input Sense Pins Serial RAM Email Send Control Pin 0 C to 70 C Send Email only Full Function V 90 FCC Part 68 Approved UL1950 listed modem CH2159 2 Input Sense Pins Email Send Control Pin Send emails with attachment 0 C to 70 C files Full Function V 90 FCC P...

Page 19: ...4 E mail cermstaf cermetek com website www cermetek com Cermetek reserves the right to make changes in specifications at any time and without notice The information furnished by Cermetek in this publication is believed to be accurate and reliable However no responsibility is assumed by Cermetek for its use or for any infringements of patents or other rights of third parties resulting from its use ...

Reviews: