42
Installation and operating instructions
Fault
4
DC INJ. High
Output DC feed-in exceeds the
permitted upper limit.
3
Rly-Check Fault Output relay has failed.
2
EEPROM R/W
Fault
Reading or writing of EEPROM fails
44
DC Inj. differs
for M-S
A different value of DC feed-in has
been detected by the master and slave
MCU.
43
Ground I differs
for M-S
A different value of residual current
has been detected by the master and
slave MCU.
42
Fac differs for
M-S
A different value of grid frequency has
been detected by the master and slave
MCU.
41
Vac differs for
M-S
A different value of grid voltage has
been detected by the master and slave
MCU.
11
M-S version
unmatched
Different firmware version between
the master and slave MCU.
38
ISO Fault
The PV generator’s insulation
resistance to earth is below the
permitted value, or the electrical
insulation inside the inverter has failed.
1
SPI Fault
Communication between the master
and slave MCU has failed.
39
Fan Lock
The fan or internal circuit has failed.
10
Device Fault
Unknown Error
The last 5 dated failure reports on the NS protection can be read. An interruption in
the supply voltage of ≤ 3s does not result in any loss of failure reports (according
to VDE-AR-N 4105).