Z21I4K8D48

5400

580

125

~

550

125

15/15

0

20

2

2(can parallel)

Lead-acid or Li-Ion

48

4600

2300, programmable

>=100 (depending requirement)

3-stage adaptive with maintenance 

57V,programmable

included(Li-Ion)

integrated

integrated

4600

4600

1.5x Pnom, 10sec

20

30

Z21I3K6D48

4200

580

125~550

125

15/15

0

20

2

2(can parallel)

Lead-acid or Li-Ion

48

3600

2300, programmable

>=100 (depending requirement)

3-stage adaptive with maintenance 

57V,programmable

included(Li-Ion)

integrated

integrated

3600

3600

1.5x Pnom, 10sec

16

24

99.9%

50/60Hz; 230Vac

45~55Hz/55~65Hz; 180~270Vac

230Vac ±2%, 50Hz (60Hz Optional)±0.2%, THDv<3%(linear load)

<1.5%

0.9 leading~0.9 lagging

Single phase

Category 

 

97.6%

97.0%

97.6%

97.0%

*

Solar

Max. DC  power(W)

Max. DC voltage (V)

MPPT voltage range (V)

Starting  voltage (V)

Max. DC current (A)

DC overcurrent protection(A)

No. of  DC connectors

No. of  MPPTs

DC overvoltage category

DC connector

Battery

Battery  Type

Norminal Voltage  (V)

MAX Discharge power (W)

MAX Charge power (W)

Battery capacity (Ah)

Charging curve

Charging voltage

Battery temperature compensation

Battery voltage sense

Current shunt

AC Output Data

Norminal AC power(W)

Max. AC power(W)

Peak power

 

(Back-up)(W)

Max. AC current(A)

AC overcurrent protection(A)

Norminal AC output 

AC output range

AC output (Back-up)

THDi

Power factor

Grid connection

AC overvoltage category

Efficiency

Max. efficiency

Euro efficiency

MPPT adaptation efficiency

**

Max inverter backfeed current to

the array(A)

IEC62109-1&-2, AS3100, IEC62040-1

30

       

28

        

516*440*184mm

516*440*184mm

Protection

Residual current monitoring unit

Anti-islanding protection

DC switch(PV)

AC over current protection

Insulation monitoring

Certifications&Standards

Grid regulation

Safety

EMC

General Data

Dimensions (WxHxD) 

Weight (kg)

Mounting 

Ambient temperature range

Relative humidity

Moisture location category

Max. operating altitude

Protection degree 

Environment category

External environment pollution degree 

Topology

Standby losses(W)

Cooling 

Noise emision(dB)

Display

Communication

Integrated

Integrated

Integrated (optional)

Integrated

Integrated

Wall-mounted 

-25~60°C

 

(>45°C derating)

0~95%

4K4H

 2000m

IP65

Outdoor & indoor

Grade1, 2, 3

Transformerless

<8

Natural convention

<25

LED light & APP

USB2.0; RS485; Wi-Fi

Bracket

Model

Z21I4K6D48

Z21I3K6D48

*

listed in the table.
**BACK-UP Load configure specification

Inductive load: Single inductive load max power 

1.5kW,Total inductive load power

2.5kW;

For example :Such as Air conditioner

Washer

Electric motor etc is inductive load;

Capacitive Load :Total capacitive load power 

3.0kVA;

For example :Such as computer

Switch power etc is capacitive load;

It is recommended that the total peak power of PV strings should not exceed 130% of maximum DC power of inverter 

VDE4105, VDE 0126-1-1/A1, 

G59/3, AS4777.2/.3

VDE4105, VDE 0126-1-1/A1, 

G83/2, AS4777.2/.3

EN61000-6-1, EN61000-6-2, EN61000-6-3, 

EN61000-6-4, EN61000-3-11, EN61000-3-12

EN61000-6-1, EN61000-6-2, EN61000-6-3,

 EN61000-6-4, EN61000-3-2, EN61000-3-3

Содержание Z21 Series

Страница 1: ...Ltd Brisbane Office 32 Cr Banyo QLD 4014 ockford Street Phone 07 31236148 Fax 07 32664758 Email salesstaff zeusappollosolar com au Perth Office 1 87 President Street Welshpool WA 6106 Phone 08 655565...

Страница 2: ...Selecting The Mounting Location 3 4 Mounting 03 03 04 05 16 01 17 18 19 21 4 1 AC Output Connection 4 2 PV Connection 4 3 Battery Connection 4 4 RS 485 Connection 4 5 EzMeter Connection 4 6 EzConverte...

Страница 3: ...d over or slung 2 2 Safety Installation maintenance and connection of inverters must be performed by qualified personnel in compliance with local electrical standards wiring rules and the requirements...

Страница 4: ...nection Guide 1 Wi Fi Connection Configuration Warranty card 1 Instruction of Fast Installation 3 3 Selecting The Mounting Location For the accessibility of monitoring the LED lights and possible main...

Страница 5: ...C terminal Refer to Figure 4 1 2 7 Compress the terminal head using an appropriate tool and screw down the screw cap slightly Refer to Figure 4 1 3 Figure 4 1 4 8 Insert AC terminals into the correspo...

Страница 6: ...ator 4 Disconnect the waterproof ring from the insulator 5 Put the cable through the components in this order screw cap waterproof ring insulator battery cover and battery terminal Refer to Figure 4 3...

Страница 7: ...Positive terminal Negative terminal Figure 4 3 6 Figure 4 3 7 Hexagon head screw Pan head screw 4 5 EzMeter Connection The EzMeter may detect the current magnitude and direction to control the working...

Страница 8: ...It will be required to configure the EzConverter if a lithium battery is used in the system to enable communication with the battery BMS Communication between the inverter and the EzConverter is via a...

Страница 9: ...igure 4 8 1 Open USB cover Touch switch 4 10 System Connection Diagram Note Not all overcurrent protection devices are included in diagram this diagram is for Australia Switch Board Grid Back Up Zeus...

Страница 10: ...NECTED NOT ACTIVE ON GRID IS ACTIVE AND CONNECTED BLINK GRID IS ACTIVE BUT NOT CONNECTED OFF GRID IS NOT ACTIVE ON CONSUMING ENERGY FROM GRID BUYING BLINK 1 SUPPLYING ENERGY TO GRID ZEROING BLINK 2 SU...

Страница 11: ...Relay Check Failure DC Injection High EEPROM R W Failure SPI Failure DC Bus High AC HCT Failure GFCI Failure Vac Failure Battery Over Temperature Battery Under Temperature Battery Cell Voltage Differ...

Страница 12: ...efficiency Euro efficiency MPPT adaptation efficiency Max inverter backfeed current to the array A IEC62109 1 2 AS3100 IEC62040 1 30 28 516 440 184mm 516 440 184mm Protection Residual current monitori...

Страница 13: ...e ambient air temperature is 20 50 C relative humidity range is 4 to 100 applied to PD3 Indoor unconditioned the ambient air temperature is 20 50 C relative humidity range is 5 to 95 applied to PD3 In...

Отзывы: