Alternator maintenance
When washing and cleaning the tractor protect the alternator from penetration of water or
diesel fuel! During operation the alternator must not be disconnected from the battery! The alternator
must never be put in operation without load, i.e. with the conductor disconnected from the '+B'
terminal and the '+D' terminal connected. Such a condition may induce an extremely high voltage
when the engine speed is increased, which would destroy the semiconductors! Never short-circuit
any alternator terminal during operation! The alternator must not be additionally excited. Such an
intervention would damage the semiconductors. Ensure perfect electric connection of the alternator
terminals and proper grounding of the alternator! Poles of the alternator may not be re-versed even
for a short time!
Electric installation overload
Is signalized by the selected display changing to a display
with a symbol of a battery. It is a condition when electric
installation of the tractor has such take-off, that the
alternator performance is not sufficient to accumulator
charging. If this state occurs, turn off a device or increase
engine revolutions, load of electric installation drops and
originally selected display is displayed.
The operation of tractor in the electric
installation overload mode can lead to accumulator
depletion.
P18N005
ELECTRICAL INSTALLATION
144
Содержание Proxima CL 80
Страница 1: ...OPERATOR S MANUAL PROXIMA CL 03 2018 Tractor is Zetor Since 1946 80 90 100 110...
Страница 3: ...2...
Страница 11: ...10...
Страница 33: ...NOTES 32...
Страница 91: ...NOTES 90...
Страница 111: ...NOTES 110...
Страница 131: ...NOTES 130...
Страница 147: ...Fuse panel B P18N083 ELECTRICAL INSTALLATION 146...
Страница 163: ...NOTES 162...
Страница 181: ...NOTES 180...
Страница 187: ...NOTES 186...
Страница 203: ...NOTES 202...
Страница 208: ...207...
Страница 210: ...Made in EU www zetor com zetor zetor com...