background image

6

WHAT ARE THE 

LIMITATIONS OF MY 

SMOKE ALARM? 

Your Zeta smoke alarm is designed to alert 

you by sounding an alarm when it senses 

smoke, i.e. it can only sense smoke and alert 

you if smoke reaches it! If a fire develops in 

an area remote from the location of the smoke 

alarm, such as another room or another level, 

smoke may not reach the smoke alarm in 

sufficient time or quantity to sense and alert 

you to the danger.
We recommend that as a minimum you install 

both ionisation and optical smoke alarms on 

every floor of your property. For comprehensive 

coverage a smoke alarm should also be fitted 

in every room.
This smoke alarm cannot be used to provide 

primary fire detection in common areas used 

by different residents such as blocks of flats 

and hotels. The Zeta smoke alarm may not 

alarm before a fire causes damage, injury or 

death, as the smoke may not reach the smoke 

alarm in time. Examples include smoking in 

bed and violent gas explosions. This smoke 

alarm may not respond in a reasonable 

time if it is not installed in the best position, 

or if furniture or other obstacles are located 

between the smoke alarm and the fire.

WARNING:

 

Your smoke alarm will not 

operate without a battery installed. Only 

batteries listed on page 14 should be used 

and must be changed immediately when the 

low battery signal is given or the unit will fail. 

Test weekly, read and follow all instructions 

or the unit will not operate properly.

Your Zeta smoke alarm will advise you of a 

low battery condition by emitting an audible 

‘chirp’ every 40 seconds. When this occurs 

you must change the battery in the unit within 

7 days to maintain correct operation.

IMPORTANT:

 

Smoke alarms are 

designed to alert you with an audible 

alarm at a level specified by the British 

Standard BS EN 14604: 2005. Closed doors, 

walls and high ambient noise levels will 

reduce this level. Temporary or permanently 

impaired hearing may result in the alarm not 

being heard. Stereos, traffic and other loud 

sources may also prevent the alarm being 

heard. Heavy sleepers and residents under 

the influence of alcohol or drugs may also 

not hear or respond to the alarm. Test and 

check that you can hear the alarm in all 

circumstances. If in doubt install additional 

smoke alarms as required.

WARNING:

 

The Smoke alarm is not 

suitable for alerting hearing impaired 

residents. We recommend that specially 

designed warning systems be installed that 

will alert hearing impaired residents.

Содержание ZD-SI-601/ZD-SO-601

Страница 1: ...ZD SI 601 ZD SO 601 User Manual EASY TO SILENCE TOAST PROOF SMOKE ALARM...

Страница 2: ...l Condition Low Battery Condition BATTERY REPLACEMENT ALARM TEST ALARM SMART SILENCE ROUTINE MAINTENANCE WHAT TO DO IN CASE OF FIRE IN YOUR HOME REPAIR TROUBLESHOOTING DISPOSAL HOW TO MAKE YOUR HOME S...

Страница 3: ...r manual fully before installing and operating the alarm If you are installing this smoke alarm for use by others you must leave this manual or a copy of it with the end user SENSOR TECHNOLOGY There a...

Страница 4: ...lly between 4 C 40 F and 38 C 100 F The type of smoke alarm used in each location should be appropriate to the environment Check the section on Positioning to ensure that the smoke alarm is to be corr...

Страница 5: ...ial commercial or industrial application nor for any other purpose than described above POSITIONING Ionisation type smoke alarms are generally more effective at detecting fast flaming fires which cons...

Страница 6: ...n clog openings to the sensing chamber preventing smoke entry or causing unwanted alarms Within 30cm 12 of a fluorescent light fitting which emits electrical noise that can prevent correct alarm opera...

Страница 7: ...rm and the fire WARNING Your smoke alarm will not operate without a battery installed Only batteries listed on page 14 should be used and must be changed immediately when the low battery signal is giv...

Страница 8: ...igned to sense smoke and alert you It will not sense carbon monoxide flames heat or gas It will not prevent or extinguish fires This Zeta smoke alarm has a limited life of 10 years and should not be c...

Страница 9: ...talling your smoke alarm the battery must be removed from the alarm and the protective wrapper on the battery should be removed The battery should then be refitted The battery compartment has been des...

Страница 10: ...eased meaning that the alarm can be attached to the backing plate 4 Fit Your Zeta Smoke Alarm The alarm will only lock into place in one particular position Position the smoke alarm over the mounting...

Страница 11: ...er failure to change the battery after this time would mean your smoke alarm has insufficient power to alert you in a real fire situation BATTERY REPLACEMENT IMPORTANT Only the following batteries can...

Страница 12: ...Replace the alarm on its mounting plate lining up the large central vent on the front of the alarm with the X that is moulded into the plastic on the mounting plate if unsure see page 13 Ensure the u...

Страница 13: ...r immediate attention Only use the alarm silence function after making sure that there is no ongoing fire emergency situation Do not block the vents on the alarm or disable the smoke alarm in any way...

Страница 14: ...will flash more rapidly than normal approximately once every 10 seconds d Your alarm will automatically return to full sensitivity on completion of the reset cycle and the red LED will revert to flas...

Страница 15: ...ection Alarm Test on page 16 Any test failures should be reported to the Zeta Technical Support Team on page 25 Cleaning As a minimum your smoke alarm should be cleaned once every 3 months using your...

Страница 16: ...sed their chances of escaping safely Go over the following rules with your children each time you have fire drills This will help everyone remember them in case of a real emergency Don t panic stay ca...

Страница 17: ...your warranty If your smoke alarm is not operating properly see the next section Troubleshooting If you cannot solve the problem please call the Technical Support Line If your Zeta smoke alarm is no l...

Страница 18: ...lightly damp cloth Your Zeta smoke alarm does not test when installed Make sure you have removed the wrapper from the battery before reconnecting Your Zeta smoke alarm chirps intermittently Check the...

Страница 19: ...unwanted alarms Check the location of your Zeta smoke alarm see the section on Positioning Clean the smoke alarm see the section on Routine Maintenance ZD SI 601 Only Remove buildup of static electric...

Страница 20: ...ght If you have any questions about the operation of your alarm please contact the Zeta Technical Support Team between 9am 5pm Monday Friday Telephone 44 0 1792 455 175 or e mail support zetaalarmsyst...

Страница 21: ...m fires You must also take steps to reduce the chances of fires starting in your home If a fire does start you must increase your chances of escaping To have a good fire safety program you must 1 Inst...

Страница 22: ...smoke alarm signal and knows how to react to it If there are small children to consider it is important to explain to them what the smoke alarm signal means Teach them that they must be prepared to le...

Страница 23: ...d workmanship under normal residential use and service for a period of 5 five years from the date of purchase in the case of the ZD SI 601 and ZD SO 601 products Provided it is returned with postage p...

Страница 24: ...team member will issue you with a returns authority number so that your product can be returned for testing To return your Zeta smoke alarm under warranty send it suitably packed and with the battery...

Страница 25: ...24 GN0503 R2...

Страница 26: ...zetaalarmsystems com Web www zetaalarmsystems com Zeta Alarm Systems Detection House 72 78 Morfa Road Swansea SA1 2EN ZD SI 601 ZD SO 601 GN0503 R2 Certificate No 330j 01 to BS EN 14604 2005 ZD SI 60...

Отзывы: