IMPORTANT SAFETY 
INSTRUCTIONS 

 
 
 
 

 

 

 

Electric Safety Measures 

 

 

No one should work alone in potentially hazardous situations. 

 

A high short-circuit current from conductive materials can cause serious burns. 

 

A licensed electrician must be present for permanent installation of equipment with hardwiring. 

 

Check that the power supply cables, plugs and sockets are in good condition. 

 

Do not use any kind of metal component without first unplugging the equipment. 

 

 
 

Batteries 

 

 

Batteries should be recycled. Leave the battery in a suitable recycling bin or return it to 
the  supplier  in  the  original  packaging  of  the  new  batteries.  Consult  the  new  battery 
instructions to obtain more information on this. 

 

 

Do not dispose of batteries by throwing them in fire, as they could explode. 

 

Do not open or cut batteries; they contain an electrolyte that is toxic and harmful to the skin and 
eyes. 

 

In  order  to  prevent  personal  injury  caused  by  hazardous  currents,  avoid  wearing  wristwatches 
and jewelry such as rings when replacing batteries. Use tools equipped with insulated handles. 

 

When replacing batteries, use the same number and type of batteries installed in the equipment. 

 

Consult your distributor to obtain information on battery equipment replacement and recycling 
batteries. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SSG1

Страница 1: ...POWER SUPPLY SOURCES SERIES SSG SSG 1 5 SSG2 5 SSG5 Instruction Manual July 12 2006 SSG 0101 All the information contained in this document may be modified without prior warning...

Страница 2: ...suitable recycling bin or return it to the supplier in the original packaging of the new batteries Consult the new battery instructions to obtain more information on this Do not dispose of batteries...

Страница 3: ...3 Checking the power supply source 3 Checks prior to installation 4 Protection against transient interferences 4 Cleaning 4 Mounting Series MPS 5 2 LED Description and Operation 6 Features of SSG Powe...

Страница 4: ...element 1 If after unpacking the Series SSG power supply source and making a visual inspection you find that it has been damaged in any way YOU SHOULD NOT carry on with installation but rather you sh...

Страница 5: ...nterferences Just like all electronic equipment this system may function irregularly when subject to electrical discharges Although no system is completely immune from electrical discharges a proper E...

Страница 6: ...ed on the wall and mark the position of the screw holes making sure that the center one is leveled The following illustration shows the box and the screw holes through the back Do not use the rear box...

Страница 7: ...ms 6 FRONT PANEL 2 LED DESCRIPTION AND OPERATION INTERNAL LEDS GENERAL FAULT SERVICE PRIMARY POWER SUPPLY FAULT BATTERY CHARGER FAULT BATTERIES NOT CONNECTED FAULT LOW BATTERY WARNING EARTH SHUNT SYST...

Страница 8: ...he primary power supply conditions The two source models are similar they are composed of a power supply module of 45W 65W and 2 x 65W for supply sources SSG1 5 SSG2 5 and SSG5 respectively and an ele...

Страница 9: ...ch is indicated after a delay of some 8 minutes in order to prevent failures due to intermittent blackouts Fault Relay Operation Connector J4 FAULT with three terminals Terminal 1 Left C common Termin...

Страница 10: ...ative OUTPUT 2 PSO2 Output 2 positive PSO2 Output 2 negative FAULT RELAY FAULT C Fault relay common FAULT NC Contact normally closed FAULT NO Contact normally open MAINS IN MAINS IN Equipment earth MA...

Страница 11: ...f a connection fault or else because they are at low discharge level and the control disconnects them for protection It blinks when the batteries are at the last level of discharge before disconnectio...

Страница 12: ...nt per output 630mA SSG 1 5 1 A SSG 2 5 2 A SSG 5 Battery charge current 300mA 7 Amp hour 600mA 17 Amp hour Charges batteries to 80 in less than 24 hours and to 100 in less than 48 hours Faulty Relay...