Zero RPC-2 Скачать руководство пользователя страница 12

 

RPC-2 REVERSE PULSE DUST COLLECTOR 

Page 11 

 

 

 

 

© 2012 CLEMCO INDUSTRIES CORP.  

  www.clemcoindustries.com  

  Manual No. 22788   

8.4 

Exhauster Assembly, Figure 8 

 
Item Description 

Stock 

No 

 

1. Motor 
 

600 cfm, 1 Hp, 115-V, 1 Ph, standard .. 12314 

 

600 cfm, 1 Hp, 230-V, 3 Ph  ................. 12310 

 

900 cfm, 2 Hp, 230-V, 3 ph, standard .. 12309 

 

900 cfm, 2 Hp, 230-V, 1 Ph  ................. 02979 

2. 

Plate, motor mount 

 600 

cfm 

 

................................................ 

12004 

 900 

cfm 

 

................................................ 

12005 

3. Housing, 

exhauster 

 600 

cfm 

 

................................................ 

12272 

 900 

cfm 

 

................................................ 

12271 

4. 

Gasket, 5/16" x 1" adhesive-backed, 

 specify 

feet 

required  ............................ 00187 

5. Paddle 

wheel 

 600 

cfm 

 

................................................ 

12334 

 900 

cfm 

 

................................................ 

12335 

6. Adaptor, 

exhauster 

 600 

cfm 

 

................................................ 

16836 

 900 

cfm 

 

................................................ 

16835 

7. 

Damper assembly, less sound foam 

 

600 cfm, 6"  .......................................... 19382 

 

900 cfm, 7"  .......................................... 18414 

8. 

Sound foam, 4 sq. ft. req’d., trim to fit  .... 12484 

 
 
 

 

 
 
 

 

Figure 8 

 

 
 

7, 8 

Содержание RPC-2

Страница 1: ...the combination of products determined by the user in his selection nor as to the compliance with regulations or standard practice of such combinations of components or products It is the responsibili...

Страница 2: ...ssages that follow this symbol to avoid possible injury or death CAUTION Caution used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in pro...

Страница 3: ...timing sequence energizes when the exhauster is turned on automatically pulsing the cartridges when the exhauster is running If the switch is OFF the timer will not energize and the cartridges will no...

Страница 4: ...ts to the RPC Control Panel Pulse Sequence Panel must also be provided by the user If the RPC Collector replaces an existing push through collector or dust bag the exhauster may be wired into the cont...

Страница 5: ...s or wires to prevent accidental disconnection while under pressure Hose disconnection while under pressure could cause serious injury 2 7 Install Manometer Refer to Section 4 4 3 0 OPERATION WARNING...

Страница 6: ...me more air but will NOT increase cleaning efficiency 4 2 4 When the frequency of the pulse cycles will not lower the differential pressure to less than 4 or if a decrease in the efficiency is noted i...

Страница 7: ...ing instructions for the manometer 4 4 2 Connect one end of the 3 16 ID tubing to one of the tubing connectors elbow at the top of the manometer by pushing it over the barbed adaptor 4 4 4 Leaving the...

Страница 8: ...to become more than a quarter full 5 1 2 Check the exhaust air during a pulse cycle If dust is emitting from the exhauster cartridges are leaking or damaged Check immediately 5 1 3 With the exhauster...

Страница 9: ...ter each cartridge install venturi tube and secure with hold down plates 6 1 8 Inspect the access door gasket replace if worn or damaged Close the access door and secure 6 1 9 Reset timer OFF time to...

Страница 10: ...7 5 2 The differential pressure gauge lines may be plugged with dust Check and clean 7 5 3 Make sure the tubing has not been inserted so far into the tube connection that it blocks the tube ends 7 5...

Страница 11: ...Fitting 1 4 NPT bulkhead 05605 8 Petcock 1 4 NPT 01993 9 Gauge pressure 11826 10 Gauge differential pressure 10188 11 Snubber fitting 15786 12 Ground lug 11639 13 Tubing 1 4 nylon specify feet requir...

Страница 12: ...cfm 2 Hp 230 V 3 ph standard 12309 900 cfm 2 Hp 230 V 1 Ph 02979 2 Plate motor mount 600 cfm 12004 900 cfm 12005 3 Housing exhauster 600 cfm 12272 900 cfm 12271 4 Gasket 5 16 x 1 adhesive backed speci...

Отзывы: