Service • 11
SERVICE
Air Curtain Velocity
Air curtain velocity is affected by stocking levels, coil frost loads, temperature, fan condition, and measurement method. Zero Zone recommends
using an Alnor
®
Velometer Jr.
®
, set to the 0-to-800 fpm range. Air velocity should be measured at the back edge of the discharge air honeycomb;
at the center of the middle door in the case (other doors have slightly lower velocity). A typical RVLC30 velocity reading is 400 to 500 feet per
minute in a fully-packed case, after the case has defrosted and pulled down to operating temperature. Air curtain velocity in a partially-packed
display case is significantly lower because more air exits the back wall duct holes.
LED Power Supplies
LED power supplies are located in the main electrical box of the RVLC30. The standard location of the electrical box is on the top of the case,
but there is an option to mount the electrical box below the case in a slide-out drawer.
. This option must be
specified on the original case order.
Содержание CRYSTAL MERCHANDISER
Страница 23: ...Illustrations RVLC30 Base Locations 21 Illustrations Figure 4 RVLC30 Base Locations Refer back to page 5...
Страница 24: ...22 Illustrations RVLC30BB Base Locations Illustrations Figure 5 RVLC30BB Base Locations Refer back to page 5...
Страница 25: ...Illustrations Case Squareness 23 Illustrations Figure 6 Case Squareness Refer back to page 5...
Страница 26: ...24 Illustrations Shim Placement Illustrations Figure 7 Shim Placement Refer back to page 5...
Страница 27: ...Illustrations Shim Orientation 25 Illustrations Figure 8 Shim Orientation Refer back to page 5...
Страница 29: ...Illustrations Spacer Block 27 Illustrations Figure 10 Spacer Block Refer back to page 6...
Страница 34: ...32 Illustrations Drain Line Illustrations Figure 15 Drain Line Refer back to page 7...
Страница 38: ...36 Illustrations Electrical Box Illustrations Figure 19 Electrical Box Refer back to page 11...