24
7. Connection unit
Function schema (also refer to corresponding. el & hyd. diag.)
ZHD 3000-150 MA
ZHD 3000-150 MA, with hydraulic Auto-tilt
(config 1, art. no. 34301TL)
Function
Lift
Lower
1
Lower
2
Tilt up
Tilt down
1
Tilt down
2
Angle indicator
for lift arm.
Open platform
alarm
Over load
protection
Activation
Signal in
B
E
E+Di3
B+C
C+E
C+E
Di3
Di4
Di5
Cs
Signal Out
U0+U2
U1+U2+U4
U1+U2+U4+U5
U0+U3
U0+U1+U3+U5
U0+U1+U3+U5+U8
-
Pa- (-).
Blocks/cancels
lift and tilt up
functions.
Connection units'
functions are
activated.
Notes
Quick opening. Signal from angle sensor, activates
valve U8, which opens oil return directly to tank.
Indicates lift arm at ground. Prevents unwanted down
tilting with hydraulic auto tilt.
Pressure guard for dropping pressure connected to
the tilt cyl side, sends (when in neutral mode)
connected signal (+) back to Di4, which in turn sends
a signal out (-) on Pa-, or provides Di4 with +signal
from a tilt sensor in the foot control unit cable set to
indicate 'platform open'.
Pressure guard for rising pressure connected to tilt
cyl side sends (when activated) +signal back
to Di5 which blocks/cancels lift and tilt up functions.
No signal in on Cs results in blocked control unit
connectors. Signal to Cs usually comes from the cabin
switch, or in cases where such a switch is not used
the +signal comes in on Cs bridged from+ on the
nearby connector.