TROUBLESHOOTING PROCEDURES
Issue
Cause
What to do
After installation,
the unit doesn’t
ZRUN
1. The power source is not turned ON.
0DNHVXUHWKHFLUFXLWEUHDNHUDQGWKHXQLW¶V
power is ON.
7KHSRZHUOLQHDQGWKHFDEOHORFNLQJFRQQHFWRU
is not connecting properly.
&KHFNWKHSRZHUFRQQHFWLRQZLWKWKHXQLWLV
connected properly.
3. The switch board or control board wirings are
disconnected.
0DNHVXUHWKHZLULQJVDWWKHVZLWFKERDUGDQG
control board are connected properly.
4. The switch board or control board is defective.
4. Change the switch board or control board.
/LJKWZRUNVEXW
blower is not
turning.
1. The blower cable is disconnected.
1. Connect the blower cable.
2. Debris or obstruction in motor.
2. Remove the debris or obstrunction.
3. Motor defective or possibly seized.
3. Change the blower.
4. Damaged capacitor.
4. Change the capacitor.
5. The switch board or control board is defective.
5. Change defective part.
The unit is
vibrating.
1. The blower is not secured in place.
1. Tighten the blower in place.
2. Damaged blower wheel.
2. Replace the blower.
3. The hood is not secured in place.
&KHFNWKHLQVWDOODWLRQRIWKHKRRG
The blower is
ZRUNLQJEXWWKH
lights are not.
1. The LED light strip connector is disconnected.
1. Connect the LED light strip connector.
2. Defective LED light strip.
2. Change the LED light strip.
3. The switch board or control board is defective.
3. Change the switch board or control board.
The unit turns on
by itself.
$VSRWOLJKWRUNLWFKHQODPSLVVKLQLQJGLUHFWO\
onto the switch controls.
1. The switch controls are light sensative. A
direct light source onto the switch controls
may disrupt switch functions.
The hood is
not venting out
properly.
1. Using the wrong size of ducting.
1. Change the ducting to at least 6” round or
higher.
2. Using the wrong type of ducting. Flexible ducting
FDQUHGXFHDLUÀRZE\XSWR
2. Change the ducting to solid rigid metal
ducting.
3. The hood might be hanging to high from the
FRRNWRS
$GMXVWWKHGLVWDQFHEHWZHHQWKHFRRNWRSDQG
the bottom of the hood within 26” and 34”
range.
4. The wind from the opened windows or opened
GRRUVLQWKHVXUURXQGLQJDUHDDUHDႇHFWLQJWKH
ventilation of the hood.
4. Close all the windows and doors to eliminate
WKHRXWVLGHZLQGÀRZ
%ORFNDJHLQWKHGXFWRSHQLQJRUGXFWZRUN
5HPRYHDOOWKHEORFNLQJIURPWKHGXFWZRUNRU
duct opening.
Tr
oubleshooting
Содержание ZAN-E24CS
Страница 2: ...www zephyronline com...
Страница 22: ...20 www zephyronline com Fan Curve Diagrams ZAN ZRV ZRO ZSA...
Страница 23: ...21 Fan Curve Diagrams...
Страница 29: ...www zephyronline com...
Страница 49: ...20 www zephyronline com Diagrammes des courbes caract ristiques des ventilateurs ZAN ZRV ZRO ZSA...
Страница 50: ...21 Diagrammes des courbes caract ristiques des ventilateurs...