ELECTRICAL REQUIREMENTS
Important:

Observe all governing codes and ordinances.
It is the customer’s responsibility:

• To contact a qualified electrical installer.

• To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70

— latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition**

and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the

ground path is adequate.
Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

IMPORTANT:

Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through metal electrical

conduit.
Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA

Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and

ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood

and at the junction box).

Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575

BEFORE INSTALLING THE HOOD

1.

For the most efficient air flow exhaust, use a straight run or as few elbows as possible.

CAUTION:

  Vent unit to outside of building, only.

2.

At least two people are necessary for installation.

3.

The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if

they perfectly fit with your cabinet/wall.

4.

Do not use flex ducting.

5.

COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air

flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork.  The

damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

6.

Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation

Systems greater than specified CFM of air movement.

The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Содержание Slope ESL-M90AS

Страница 1: ...JAN06 0101...

Страница 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...d 6 Parts not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Desc...

Страница 4: ...his Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and gr...

Страница 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Страница 6: ...Cover support bracket 5 x 45 screws x 3 2 to fix Lower support bracket 1 for securing hood 9 5x3 5 screws x 6 to fix hood canopy to blower unit housing 2 9x6 5 screws x 4 to fix duct cover Allen spann...

Страница 7: ...ing surface ceiling CenterLine 11 1 2 21 1 8 11 11 Ducting and conduit area passage Duct bends are not considered max 51 15 16 min 36 6 5 8 19 5 8 11 5 8 16 5 16 12 13 16 12 13 16 35 6 16 max 45 11 16...

Страница 8: ...For ductless recirculating version only purchase the Ductless Recirculating Kit Minimum Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessa...

Страница 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Страница 10: ...n Figure below 5 Place the lower support bracket on the template making it coincide with the traced triangle mark center of two fastener location and one lower fastener location then remove template C...

Страница 11: ...he lower support bracket with wood screws supplied in mounting hardware kit on locations marked on template then remove template 13 Install duct cover support bracket to wall flush to ceiling with dry...

Страница 12: ...Level the appliance using a carpenters level across bottom of hood with leveling screws in mounting hooks 17 Secure hood with 1 screw on bottom Duct cover support bracket Lower support bracket Hooks...

Страница 13: ...R NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Facing the front of the range hood remove the left knockout and the Junction box cover and install the con...

Страница 14: ...towards the bottom 26 Fix lower duct cover to canopy with 2 screws Duct cover support bracket Duct cover support bracket Upper duct cover Lower duct cover TOP VIEW Note consider this drawings as inst...

Страница 15: ...m Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Hood canopy 6 Duct cover 7 Air outlet used for Ductless vers...

Страница 16: ...he control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extraction mode and no charcoal filter is fitted In this case perform the signal reset...

Страница 17: ...t If the cooker hood s Control Ball flashes green orange red in sequence then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructi...

Страница 18: ...ressive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not...

Страница 19: ...surrounding area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filt...

Страница 20: ...abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with eq...

Страница 21: ...rt Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm EBI 600A EBN 1100A ZRC 00SA Z0F C060 Z1C 00SL halogen bulb 12V 20 W m...

Страница 22: ...22...

Страница 23: ...23 www zephyronline com...

Отзывы: