hood 

- Control 

Ball

CONTROLS

Use the high suction speed in cases of concentrated kitchen vapours.  It is recommended that the cooker hood suction

is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes

approximately  after  terminating  cooking.

Description of control ball and hood operation

The control ball is also a light signal:

•

No signal :

The hood is switched off.

•

Static green light :

Hood is switched on at power level 1 (minimum).

•

Static orange light :

Hood is switched on at power level 2 (medium).

•

Static red light :

Hood is switched on at power level 3 (maximum).

•

Flashing red light :

Hood is switched on boost mode (timed at 5 minutes)

•

Flashing green light :

Indicates the grease filter saturation  - clean the grease filter

•

Flashing orange light :

Indicates the charcoal filter saturation  - clean or replace the charcoal filter.

Attention!

The control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the

extraction mode and no charcoal filter is fitted.

In this case, perform the signal reset operation as follows: select the boost mode (the control ball lights up with a

red flashing light), press again and hold pressed for about 3 seconds until an audible signal indicates the reset has

taken place.

Reset filter saturation signal

Green or orange flashing light

Proceed  as  follows:

Select the boost mode (the control ball switches on with flashing red light), depress again and hold for 3 about seconds

until the beep sound indicating that reset has occurred.

Switching on the cooker hood

The control ball is a balance wheel switch.

Depressing the control ball towards the right repeatedly switches on the cooker hood and all the suction speed

selections up to the boost mode, depressing again towards the right the cooker hood switches off.

Turning on the light

Depress the control ball towards the left:

once for dim lighting,

pressing  again  for  full  lighting,

pressing  again  switches  the  light  off.

Содержание Slope ESL-M90AS

Страница 1: ...JAN06 0101...

Страница 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...d 6 Parts not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Desc...

Страница 4: ...his Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and gr...

Страница 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Страница 6: ...Cover support bracket 5 x 45 screws x 3 2 to fix Lower support bracket 1 for securing hood 9 5x3 5 screws x 6 to fix hood canopy to blower unit housing 2 9x6 5 screws x 4 to fix duct cover Allen spann...

Страница 7: ...ing surface ceiling CenterLine 11 1 2 21 1 8 11 11 Ducting and conduit area passage Duct bends are not considered max 51 15 16 min 36 6 5 8 19 5 8 11 5 8 16 5 16 12 13 16 12 13 16 35 6 16 max 45 11 16...

Страница 8: ...For ductless recirculating version only purchase the Ductless Recirculating Kit Minimum Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessa...

Страница 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Страница 10: ...n Figure below 5 Place the lower support bracket on the template making it coincide with the traced triangle mark center of two fastener location and one lower fastener location then remove template C...

Страница 11: ...he lower support bracket with wood screws supplied in mounting hardware kit on locations marked on template then remove template 13 Install duct cover support bracket to wall flush to ceiling with dry...

Страница 12: ...Level the appliance using a carpenters level across bottom of hood with leveling screws in mounting hooks 17 Secure hood with 1 screw on bottom Duct cover support bracket Lower support bracket Hooks...

Страница 13: ...R NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Facing the front of the range hood remove the left knockout and the Junction box cover and install the con...

Страница 14: ...towards the bottom 26 Fix lower duct cover to canopy with 2 screws Duct cover support bracket Duct cover support bracket Upper duct cover Lower duct cover TOP VIEW Note consider this drawings as inst...

Страница 15: ...m Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Hood canopy 6 Duct cover 7 Air outlet used for Ductless vers...

Страница 16: ...he control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extraction mode and no charcoal filter is fitted In this case perform the signal reset...

Страница 17: ...t If the cooker hood s Control Ball flashes green orange red in sequence then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructi...

Страница 18: ...ressive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not...

Страница 19: ...surrounding area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filt...

Страница 20: ...abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with eq...

Страница 21: ...rt Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm EBI 600A EBN 1100A ZRC 00SA Z0F C060 Z1C 00SL halogen bulb 12V 20 W m...

Страница 22: ...22...

Страница 23: ...23 www zephyronline com...

Отзывы: