background image

4

Import

ant 

safety 

Notice

CAUTION:

FOR GENERAL VENTILATING USE ONLY.  DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR

VAPORS.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.

Use this unit only in the manner intended by the manufacturer.  If you have questions, contact the manufacturer.

B.

Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to

prevent power from being switched on accidentally.  When the service disconnecting means cannot be locked,

securely fasten a prominent warning device, such as a tag, to the service panel.

C.

Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All  Applicable Codes

& Standards, Including Fire-rated Construction.

D.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning

equipment to prevent back- drafting.  Follow the heating equipment manufacturers guideline and safety standards such

as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration

and Air Conditioning Engineers (ASHRAE), and the local code authorities.

E.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

F.

Ducted systems must always be vented to the outdoors.

CAUTION:

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces

within walls, ceilings, attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

Install this hood in accordance with all requirements specified.

WARNING

To Reduce The Risk Of  Fire Or  Electric Shock, Do Not Use This Hood With Any External Solid State Speed

Control Device.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

a)   Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite.

Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee,

Peppercorn Beef Flambe’).

c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter.

d) Use proper pan size.  Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE

FOLLOWING

:

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric

element.  BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE

FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN - you may be burned.

c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

d) Use an extinguisher 

ONLY

 if:

1)

You know you have a class ABC extinguisher, and you already know how to operate it.

2)

The fire is small and contained in the area where it started.

3)

The fire department is being called.

4)

You can fight the fire with your back to an exit.

OPERATION

a. Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair,

fingers  and  loose  clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,

maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to

negligence and the warranty of the unit automatically expires due to improper maintenance.

* NOTE: Please check our website for revisions before doing any custom work.

READ AND SAVE THESE INSTRUCTIONS

Содержание Slope ESL-M90AS

Страница 1: ...JAN06 0101...

Страница 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...d 6 Parts not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Desc...

Страница 4: ...his Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and gr...

Страница 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Страница 6: ...Cover support bracket 5 x 45 screws x 3 2 to fix Lower support bracket 1 for securing hood 9 5x3 5 screws x 6 to fix hood canopy to blower unit housing 2 9x6 5 screws x 4 to fix duct cover Allen spann...

Страница 7: ...ing surface ceiling CenterLine 11 1 2 21 1 8 11 11 Ducting and conduit area passage Duct bends are not considered max 51 15 16 min 36 6 5 8 19 5 8 11 5 8 16 5 16 12 13 16 12 13 16 35 6 16 max 45 11 16...

Страница 8: ...For ductless recirculating version only purchase the Ductless Recirculating Kit Minimum Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessa...

Страница 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Страница 10: ...n Figure below 5 Place the lower support bracket on the template making it coincide with the traced triangle mark center of two fastener location and one lower fastener location then remove template C...

Страница 11: ...he lower support bracket with wood screws supplied in mounting hardware kit on locations marked on template then remove template 13 Install duct cover support bracket to wall flush to ceiling with dry...

Страница 12: ...Level the appliance using a carpenters level across bottom of hood with leveling screws in mounting hooks 17 Secure hood with 1 screw on bottom Duct cover support bracket Lower support bracket Hooks...

Страница 13: ...R NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Facing the front of the range hood remove the left knockout and the Junction box cover and install the con...

Страница 14: ...towards the bottom 26 Fix lower duct cover to canopy with 2 screws Duct cover support bracket Duct cover support bracket Upper duct cover Lower duct cover TOP VIEW Note consider this drawings as inst...

Страница 15: ...m Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Hood canopy 6 Duct cover 7 Air outlet used for Ductless vers...

Страница 16: ...he control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extraction mode and no charcoal filter is fitted In this case perform the signal reset...

Страница 17: ...t If the cooker hood s Control Ball flashes green orange red in sequence then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructi...

Страница 18: ...ressive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not...

Страница 19: ...surrounding area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filt...

Страница 20: ...abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with eq...

Страница 21: ...rt Ductless Recirculating Kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm EBI 600A EBN 1100A ZRC 00SA Z0F C060 Z1C 00SL halogen bulb 12V 20 W m...

Страница 22: ...22...

Страница 23: ...23 www zephyronline com...

Отзывы: