background image

NOTE: If this hood replaces another one, please note that the location of the air exhaust

can vary from one manufacturer to another.

5. INSTALL THE  ADAPTER/DAMPER

Fold down the foldable flange (

C

) of the

adapter/damper. This flange must be at 90°
from the remaining flanges. Use the lower
screw holes on each side of the
adapter/damper to assemble it to the back
of hood. See below.

- 6 -

It may be necessary to adjust the
adapter/damper location to the existing wall
discharge opening. Leave  the foldable
flange (

C

) of the adapter/damper as is. Use

the upper screw holes on each side of the
adapter/damper to assemble it to the back
of hood. See below.

H

ORIZONTAL DISCHARGE

,

NEW INSTALLATION

H

ORIZONTAL DISCHARGE

,

HOOD REPLACEMENT

4. PREPARE THE  HOOD

Remove both filters from the hood.
Disassemble the adaptor/damper (

A

) from the

hood.

NOTE: The adapter/damper is located inside

the hood. Remove the bottom panel
(

B

) to access the adapter/damper.

Refer to figure beside.

HO0093

A

B

Punch out the electrical and discharge knock-outs for the chosen opening (vertical on top or
horizontal at the back of the hood). Refer to figure below.

HD0219

V

ERTICAL

D

ISCHARGE

H

ORIZONTAL

D

ISCHARGE

HJ0008

C

HJ0009

C

Содержание ES1-E30AB

Страница 1: ...USE AND CARE INTENDED FOR DOMESTIC COOKING ONLY INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER CLEANING AND OPERATION INFORMATION ON PAGES 9 AND 10 06683 rev A DEC07 0101 READ AND SAVE THESE INS...

Страница 2: ...ccumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS INTHE EVENT OF A RANGETOP GREASEFIRE OBSERV...

Страница 3: ...no 2 Hammer and flat blade screwdriver to open the knockout holes Sheet metal sheers Pair of pliers Scissors to cut duct tape Pen Wire stripper TABLE OF CONTENTS 1 INSTALL DUCTWORK 4 2 MEASURE THE IN...

Страница 4: ...und duct Roof cap Wall cap 3 x 10 to 6 round transition HH0014A 2 MEASURE THE INSTALLATION Dimensions for the most common installations are shown below We recommend to install the hood at a minimum of...

Страница 5: ...A 7 8 1118 C L 3 5 5 1 HD0151A A CABINET BOTTOM B 3 8 1 10 5 3 PREPARE THE INSTALLATION Make sure the following items are included Hood Filters 2 Adapter damper assembly 3 x 10 located inside the hoo...

Страница 6: ...foldable flange C of the adapter damper as is Use the upper screw holes on each side of the adapter damper to assemble it to the back of hood See below HORIZONTAL DISCHARGE NEW INSTALLATION HORIZONTAL...

Страница 7: ...Install the last 1 2 double thread screw B in the remaining embossed hole HD0218 NOTES 1 For the best ventilation performance if a round duct must be used the duct diameter must be 6 or more Use a 3 x...

Страница 8: ...ing must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent...

Страница 9: ...luorescent lamps may produce a yellowish lighting on first usages This temporary effect will disappear by itself WARNING In order to prevent the risk of personal injury the fluorescent tubes must be c...

Страница 10: ...residues reach the hood During construction or renovation cover the hood to make sure no dust adheres to stainless steel surface STAINLESS STEEL CLEANING NOTE Do not try to remove the black part C at...

Страница 11: ...ss on this switch to stop the blower operation B SPEED BLOWER SWITCHES Press on left switch 1 to turn on the blower on low speed on middle switch 2 to turn on the blower on medium speed and on right s...

Страница 12: ...www zephyronline com...

Страница 13: ...ces outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and w...

Отзывы: