background image

4

Import

ant 

safety 

Notice

CAUTION:

FOR GENERAL VENTILATING USE ONLY.  DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS

OR VAPORS.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.

Use this unit only in the manner intended by the manufacturer.  If you have questions, contact the manufacturer.

B.

Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to

prevent power from being switched on accidentally.  When the service disconnecting means cannot be locked, se-

curely fasten a prominent warning device, such as a tag, to the service panel.

C.

Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All  Applicable Codes

& Standards, Including Fire-rated Construction.

D.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning

equipment to prevent back- drafting.  Follow the heating equipment manufacturers guideline and safety standards such

as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration

and Air Conditioning Engineers (ASHRAE), and the local code authorities.

E.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

F.

Ducted systems must always be vented to the outdoors.

CAUTION:

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces

within walls, ceilings, attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

Install this hood in accordance with all requirements specified.

WARNING

To Reduce The Risk Of  Fire Or  Electric Shock, Do Not Use This Hood With Any External Solid State Speed

Control Device.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

a)   Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite.

Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee,

Peppercorn Beef Flambe’).

c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter.

d) Use proper pan size.  Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE

FOLLOWING

:

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric

element.  BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE

FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN - you may be burned.

c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

d) Use an extinguisher 

ONLY

 if:

1)

You know you have a class ABC extinguisher, and you already know how to operate it.

2)

The fire is small and contained in the area where it started.

3)

The fire department is being called.

4)

You can fight the fire with your back to an exit.

OPERATION

a. Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair,

fingers and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,

maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negli-

gence and the warranty of the unit automatically expires due to improper maintenance.

* NOTE: Please check our website for revisions before doing any custom work.

READ AND SAVE THESE INSTRUCTIONS

Содержание Elica Concave ECO-M90AS

Страница 1: ...JAN06 0101...

Страница 2: ...ave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...ed 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description of the hood...

Страница 4: ...Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Страница 5: ...l local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed m...

Страница 6: ...uide Control Ball with molex plug 6x70 screws x 4 to fix Duct cover brackets 10x60 wall anchors x 4 to fix Duct cover brackets 5 x 45 screws x 3 2 to fix Lower support bracket 1 for securing hood 2 9x...

Страница 7: ...inet Side Cabinet 35 7 16 min cabinets opening widths 24 to 32 bottom of canopy to cooking surface ceiling CenterLine 11 1 2 23 1 4 13 3 8 Ducting and conduit area passage Duct bends are not considere...

Страница 8: ...it Minimum Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed...

Страница 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Страница 10: ...studs otherwise proceed as follows Cutout drywall along marked lines Install each necessary between studs firmly flush with already existing stud front Make sure all mounting screws will anchor to ad...

Страница 11: ...f the blower unit inside 15 Hang the blower unit housing with the 2 mounting hooks WARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in...

Страница 12: ...IN YOUR HOME ELECTRICAL SYSTEM AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Facing the front of the range hood remove the left knockou...

Страница 13: ...serves to hang the decorative panel Use pins 2 upper fixing screws and 1 at the bottom to fix the decorative panel Check that panel is firmly fixed on its position Rear View Installation 21 Fit contro...

Страница 14: ...ilter housing electronic box and cables are acces sible Note temporarily fix the duct covers to inte gral ventilator housing with two screws FRONT VIEW REAR VIEW Rails location Duct covers Integral mo...

Страница 15: ...stall upper duct cover to its upper support with 2 screws 1 per side Note Upper Duct Cover may be placed upside down to hide or unhide ventless slots 27 Check all light bulbs to make sure they are sec...

Страница 16: ...on of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Vapour screen 6 Duct cover 7 Air outlet used for Ductless version only...

Страница 17: ...on The control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extraction mode and no charcoal filter is fitted In this case perform the signal re...

Страница 18: ...e cooker hood s Control Ball flashes green orange red in sequence then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructions bel...

Страница 19: ...nth using non aggressive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly...

Страница 20: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Страница 21: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Страница 22: ...uctless conversion kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm EBI 600A EBN 1100A ZRC 00CS Z0F C060 Part Description Part halogen bulb 12V...

Страница 23: ...2 3 www zephyronline com Exploded View Diagram...

Страница 24: ...2 4 Part Numbers...

Отзывы: