10
www.zephyronline.com
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal fi lters are required on top of its standard
Aluminum Mesh Filter set. Order according to its Part number below. The standard Aluminum Mesh Filters
are intended to capture residue from cooking and the optional charcoal fi lters help to purify fumes exhausted
from cooking for re-circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal fi lters and air diverter plate.
Hood Model
Part No.
Filters in Pkg.
ZRV-E30AG / ZRV-M90AG
ZRC-00RV
2
1. Purchase recirculating kit per the part number above
2. Secure air diverter plate to wall below duct cover bracket. (FIG.
C) Run 6” ducting from top of hood and secure to air diverter
plate.
See manual included with recirculating kit for more
detailed instructions.
3. Remove aluminum mesh fi lter from hood. Install charcoal fi lter
bracket inside fi lter opening. Note: screws to secure charcoal
fi lter bracket are already pre-installed in the hood and must fi rst
be removed. Clip charcoal fi lters onto charcoal fi lter bracket.
(FIG. C)
4. Re-Install aluminum mesh fi lter.
5. Enable charcoal fi lter change indicator on control panel. (Refer
details to pg. 12)
6. Charcoal fi lters must be replaced after every 120 hours of use
(or approximately every 3 to 4 months based on the average
of 1 - 2 hrs. of daily cooking time). The microprocessor in
the controls when set, will elapse and count usage time and
indicate when charcoal fi lter replacement is required every 120
hours.
Charcoal Filter Replacements
Hood Model
Part No.
Qty to Order
ZRV-E30AG / ZRV-M90AG
Z0F-C002 2
DO NOT WASH CHARCOAL FILTERS. Charcoal fi lters may need
to be changed more often depending on cooking habits.
Installation –