   801525NZ - Chilled HydroTap Installation Instructions - Aug 2015 - v2.00

WARNINGS

1. 

The Zenith HydroTap unit must be earthed. The resistance of the earth connection from each exposed 
metal part must be less than 1 ohm.

2. 

All Installation and service work must be completed by trained and suitably qualified Tradespeople. 
Faulty operation due to unqualified persons working on this product, or any other Zenith product may 
void warranty coverage.

3. 

All Plumbing must comply with AS/NZS3500.

4. 

All Electrical must comply with AS/NZS3000

5. 

All Plumbing and Electrical connections must be made in accordance with local regulations.

6. 

This HydroTap product is rated for 230V 50Hz AC operation.

7. 

Undersink units must never be located near, or cleaned with water jets.

8. 

Zenith HydroTaps are not to be exposed to the elements of nature

9. 

Due to the process of continuous improvement, Zenith Heaters reserves the right to change details 
mentioned in this manual, without notice.

Important Safety Instructions

This manual contains important safety, installation instructions for the Zenith HydroTap G4.
This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and above and 
persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 
have been given supervision or instruction concerning use of the appliance in a safe way and understand 
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be 
made by children without supervision.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all 
installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power 
outlet must be in a safe visible position for connection.

Lifting

Take care when lifting the Zenith HydroTap unit. Some units may exceed safe lifting limits. If you feel this is 
beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked 
on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to 
page 7 for the weight of your product. 

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. Proper air circulation must be 
provided. The system will operate satisfactorily only if the recommended air gaps are provided. If a vent kit is 
supplied it must be fitted. See technical specifications for correct installation to prevent overheating. 

Positioning

It is important to ensure the undersink unit is positioned in an accessible area close to the floor level. The unit 
must have it’s base mounted in a horizontal position with all inlets and outlets facing up. The Tap must be 
located above the undersink unit. See section 1.

in an area that may be cleaned by a water jet and must 

not be cleaned by a water jet.

                                                            

Содержание HydroTap G4 Celsius C125

Страница 1: ...1 of 20 Zenith HydroTap Installation Instructions Affix Model Number Label Here 801525NZ Filtered Chilled drinking water for commercial kitchens and tea rooms The G4 applaince series offers a range o...

Страница 2: ...Page 2 of 20 801525NZ Chilled HydroTap Installation Instructions Aug 2015 v2 00 Notes...

Страница 3: ...P 1 Measure and cut all the tap holes before fitting the taps Section 1 Tap Installation instructions 1 1 HydroTap Tap installation 9 13 STEP 2 Check for adequate ventilation Section 2 Ventilation 2 1...

Страница 4: ...rd supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have b...

Страница 5: ...dispensing tap mounted on a sink or bench which may be used for commercial applications These units utilise a conventional refrigerant compressor to chill the water which is factory set to 5 9 C Thes...

Страница 6: ...from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the app...

Страница 7: ...cription Font Kit for Arc Cube Models Font Kit for Classic Elite Models Replacement Filter Disabled lever Kit Guide Commercial Models C Chilled filtered D Disabled lever controls Order as an option Mo...

Страница 8: ...h isolating valve inside the cupboard within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed A co...

Страница 9: ...ce for a cup or tea pot Alternatively the tap could be mounted away from the sink using a Zenith Font available as an accessory Section 1 Tap Installation 116 BC HydroTap Check bowl depth and adjust a...

Страница 10: ...on the underside of the spacer to ensure a watertight fit 1 2 Cut a 35mm hole in the bench sink top BENCH TOP 1 1 35mm ALL THREAD ROD STAINLESS STEEL SPACER SPIDER CLAMP NUT BLACK PLASTIC SPACER Tap...

Страница 11: ...e legs of the SPIDER CLAMP when installing Fit the STAINLESS STEEL WASHER SPIDER CLAMP AND 6mm NUT 6mm NUT SPIDER CLAMP STAINLESS STEEL WASHER Blue hose to chilled water outlet Incoming water Blue hos...

Страница 12: ...elected holes NOTE When determining which of the 6 holes are required for the new spout height and orientation check the new plastic clip position will clear the undercut and that the wiring loom will...

Страница 13: ...nd Control Right Hand Control B C C B 50mm Height adjustment Fixed position options Angular adjustment Fixed position options 1 7 O RING LOWER RUBBER WASHER WASHER NUT 1 8 1 9 Mounting See table on Pa...

Страница 14: ...ommended to install vent duct and louvre panels for under floor and or door vent systems Note Inlet and outlet vents should be separated by a Min 100mm to avoid hot air recirculation IMPORTANT See pag...

Страница 15: ...ons where the cupboard space temperature is near 35 C or higher an auxillary ventilation kit must be fitted contact your local service centre for availability Note The vent kit has to be installed in...

Страница 16: ...nk Unit Installation BLUE BRAIDED 3 1 Hose and tube fitting Do not overtighten Remove all caps from the top of the undersink unit Fit the foam insulation to the Blue tube after trimming to length Inst...

Страница 17: ...ished Turn the stop cock OFF then press Stop to end filter flush mode 5 Press Next and the View screen will show the Flow calibration mode Have a 10L bucket or similar container not supplied at the re...

Страница 18: ...tructions Aug 2015 v2 00 Commissioning 4 3 Flow Calibration 1 Press the Start button and the tank will first empty then fill This will take aprox 5 minutes 2 Upon completion the actual pulse will be d...

Страница 19: ...OverRun Compressor too Hot Check ventilation Water Supply Failure No water Check water supply is turned ON Cold Sensor Open Internal fault Call Zenith Service Cold Sensor Closed Internal fault Call Ze...

Страница 20: ...065848 US4354049 US5103859 US5099825 and SA2006 08043 Other patents are in force and patent applications are pending Head Office Zenith Heaters Limited IRD No 95 640 729 Unit 2 15 Moselle Avenue Hende...

Отзывы: