SPA-V2 Public Address & General Alarm System
Installation & Configuration Manual
Figure 2
Cabinet measurements front, side & rear
Please take note of the following:
● Cable inlets should be realized through the rear of the cabinet.
-
The two 75 x 65 mm slots at the rear of the base are NOT
recommended for cable inlets.
● For big and heavy racks, remove the heavy amplifiers before
mounting. (It may be necessary with other fastening arrangements.)
●
There are four 12 mm fastening holes for mounting the rack to the
floor as standard.
●
There are air ventilation slots on both sides and rear of all units.
●
Free space on both sides should be minimum 300 mm.
●
There is free space (134 mm) at the rear side of the rack for a cable
run from the wall.
●
The rack should be mounted at least 300 mm from the wall.
●
Racks from 20HU and higher must be fastened at the top to the wall.
(see figure)
Figure 3 Fastening for 20U and higher racks
After installation, all cable termination, sub-boards and internal system
equipment can be accessed by removing the lower front cover panels.
FASTENING TO WALL
SIDE VIEW
300 mm