2.8
Jumper Settings for Configuration of Functions
The jumpers are normally set according to project specifications
at delivery, but may be changed if modifications are required after
installation.
2.8.1
Jumper settings on SPA Terminal Board
Entertainment output selection
Jumper J25 in right position (default setting):
-
Entertainment audio on the ‘Audio out to amplifiers’ terminal X3.
-Entertainment will then have lowest priority and be overridden by
any messages and alarms.
Figure 6
Jumper for Entertainment Output to external system
Jumper J25 in left position:
-Entertainment audio on the ‘Entertainment output’ terminal X6 for
connecting to external entertainment system.
-The entertainment program will be present on this terminal
independent of other ongoing messages in the system.
Audio Input from Talk-Back X7
Jumper J17 in upper position (default setting):
-Audio from the Talk-back unit is connected to minus.
Figure 7 Jumper for audio from Talk-Back system
-If audio output 0dB from Talk-Back is connected both to SPA and a
100V Talk-Back system, the Jumper J17 must be set to the lower
position.
Alarm Priority
Default setting:
-
Jumper PRIO.1, PRIO.2 and PRIO.3 in upper (N) position, and
PRIO.4 in lower position.
X4
X5
X6
X7
X8
X11
X15
X14
X13
X2
X1
EX
T
E
R
N
A
M
P
LIF
I
E
R
P
A
-M
U
T
E
P
O
TF
R
EE
O
U
T
PU
T
E
N
T
E
R
T.
O
U
T
PU
T
A
U
D
IO
O
U
T
TO
A
M
P
LIF
I
E
R
A
LA
R
M
IN
PU
T 1
P
A
B
X
IN
PU
T
A
LA
R
M
IN
PU
T 2
M
IC
R
O
P
H
O
N
E
IN
PU
T 1
10
0
V
L
IN
E
O
U
T
TA
L
K
-B
A
C
K
C
TB
/E
TB
IN
PU
T
P
O
W
E
R
SU
PP
LY
24
V
D
C
E
M
E
R
G
E
N
C
Y
P
O
W
E
R
24
V
D
C
+
+
X3
X10
M
IC
R
O
P
H
O
N
E
IN
PU
T 3
X9
X12
P
A
B
X
C
A
LL
M
O
D
U
L
E
A
M
P
LIF
I
E
R
IN
PU
T
M
IC
R
O
P
H
O
N
E
IN
PU
T 2
SP
A
-R
E
L O
VE
R
R
ID
E
N
N
N
N
PRIO.2
N
N
PRIO.3
PRIO.4
J
21
J
22
J
23
J
28
J
6
J
7
J
8
IX3
IX2
IX1
N
N
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
1
2
3
1
2
3
1
2
1
2
3
4
5
EXT. CON. FOR CHIME
X18
1
2
3
4
5
1
2
3
4
5
6
7
8
990-552 SPA-TERMINALBOARD V3
IX4
IX5
IX6
IX7
IX8
IX9
IX10
IX11
1
2
3
1
2
3
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
1
2
3
1
2
3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
1
2
3
ALARM PRIORITY
FIRE CREW
ENTERTAINMENT OUT
TALK BACK SELECT
PABX ZONES
ZONE SELECTION
EXTERN AMPLIFIER
OVERRIDE
MIC. 2 VOL.
VOL.TO AMP.
TALK BACK
CTB/ETB VOL
ENT. VOL
ENT. OUT
MIC. 1 VOL.
PRIO.1
MIC. 3 VOL.
PABX VOL.
J
26
FR
O
M
A
LA
R
M
M
O
D
U
L
E
F
U
SE
1A
F2
F
U
SE
1A
F1
N
N
PRIO.1
N
N
PRIO.2
N
N
PRIO.3
PRIO.4
J
21
J
22
J
23
J
28
J
6
J
7
J
8
J
26
ENT. VOL
N
N
ENT. OUT
TALK BACK
ZONE ALL - TB ON/OFF
EMS+ALL - EMS ONLY
J
2
J
3
J
4
J
5
INT./EXT. 24V OVERRIDE
INT. - EXT.
N / EMS
N
N
PRIO.1
N
N
PRIO.2
N
N
PRIO.3
PRIO.4
J
21
J
22
J
23
J
28
J
6
J
7
J
8
J
26
ENT. VOL
N
N
ENT. OUT
TALK BACK
ZONE ALL - TB ON/OFF
EMS+ALL - EMS ONLY
J
2
J
3
J
4
J
5
INT./EXT. 24V OVERRIDE
INT. - EXT.
N / EMS