User Manual
Technical specifications
General
Crystal Frequency:
4,915200 MHz.
Accuracy:
0,1 sec./24 hours (at +20°C).
Microprocessor:
HD6412394.
Connection voltage:
100 - 240V 50/60 Hz and. 24 V DC -5% +20 %.
Max ripple (24V DC):
0,7V RMS.
Power consumption:
65 W (max)
Ambient temperature:
Between 0° C and +50°C.
Relative humidity:
Max. 85% non-condensing.
IP rating:
IP20
Weight:
5.6 kg.
CE-Approval, EMC:
Emission acc. to EN61000-6-3, Immunity acc. to. EN61000-6-2.
Slave Clock output
Output 1, 2 and 3:
Impulse system:
1/1 minute, 1/2 minute, second, Time Code (TC)
Type of time:
LT, UTC
Impulse length:
Minute 0.1-9.9 sec. Second 0.1-1 sec.
Output 4:
Impulse system:
2-wire: 1/1 minute, 1/2 minute, second, Time Code (TC).
3-wire for Forward/Reverse movement: 1/1-minute alt. 1/2-minut.
Type of time:
LT, UTC
Impulse duration:
Minute 0.1-9.9 sec. Second 0.1-1 sec.
Impulse voltage:
24VDC
Maximum load / output:
2A (The output is equipped with short circuit protection that resets automatically)
Total load all outputs:
2.5A
Relay output
Relay outputs:
2 closing potential-free
contacts.
Max. load/relay output:
24 VDC/AC 2A.
Program memory:
100 years (EEPROM)
Number of control functions: 800.
Alarm output
Number of outputs:
2 Changeover potential-free
contacts.
Max. load/relay output:
24VDC/AC 2A.
Type of alarms
Output no. 1 (general alarm): Overload / short circuit, synchronization alarm
Output no. 2 (power alarm): Power failure alarm
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Содержание Marine Master Clock 70000
Страница 1: ...MASTERCLOCKSYSTEM TECHNICAL USER MANUAL A100K10807 TECHNICAL MANUAL...
Страница 114: ......
Страница 116: ......
Страница 117: ...www zenitel com ZenitelNorwayAS...