Document: 1717en21.doc
Author: PM
Date: 2022-06-22
Page: 38 of 57
MARINE MASTER CLOCK
User Manual
Setup sync. source
Below is a description of the different configuration parameters available in the setup menu for sync. source.
Please remark that if default settings are used no configuration is needed.
Type of synchronization
State type of external synchronization. The following time sources can be selected:
NMEA RS485 (default) Synchronization using RS485 input and NMEA ZDA protocol.
NMEA RS232
Synchronization using RS232 input and NMEA ZDA protocol.
W-GPS
Radio synchronization GPS type Westerstrand.
DCF77
Radio synchronization DCF77.
TC
Time code type hard wired DC
--------
No external synchronization
.
Alarm limit
The configuration parameter Alarm limit specifies the time delay before the radio alarm is activated. Default
setting is that the radio alarm is inactivated, AL.LIMIT --h--m.
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Type of synchronization
NMEA RS485
AL. LIMIT --h--m