MARINE MASTER CLOCK
User Manual
Protocol 2
The message has length 20 bytes according to:
STX F G W 20 YY MM DD HH MM SS ETX BCC
F - Flag bits
7
=0
6
=1
5
=0
4
=0 Winter time, =1 summer time
3
=1 Synced from Radio source, e.g. DCF77
2
=1 Synched from timeserver
1
0
Type of time
OFF OFF
UTC
OFF ON
LOC
ON OFF
NOR
Example:
Assume wintertime time, synched from radio source, synchronized from timeserver, local time:
Bits 6, 3, 2 and 0 are set: 0100 1101 = 4Dh = 'M'
G - UTC offset during wintertime from letter 'P' in 1/2 hour steps.
Example:
Germany 2 x 1/2 = 1 hour, so 'P'+2 = 'R'
W
Weekday
'1' Monday .. '7' Sunday
YY
Year
'00'..'99'
MM
Month
'01'..'12'
DD
Day of month
'01'..'31'
HH
Hour
'00'..'23'
MM
Minute
'00'..'59'
SS
Second
'00'..'59'
ETX
03h
BCC
Exclusive or of bytes F..ETX
The message is transmitted each second