Document: 1717en21.doc
Author: PM
Date: 2022-06-22
Page: 57 of 57
MARINE MASTER CLOCK
User Manual
5
NO
output no. 1
Connector: 3-polar screw terminal, max. conductor
size 2.5mm
2
.
24VAC/DC 2A
6
Common
Program relay
output no. 2
Common, NC, NO
Connector: 3-polar screw terminal, max. conductor
size 2.5mm
2
.
Max. load:
24VAC/DC 2A
7
NO
8
Common
Power alarm
relay output
Common, NC, NO
Connector: 3-polar screw terminal, max. conductor
size 2.5mm
2
.
Max. load:
24VAC/DC 2A
9
NO
10
NC
11
Not used
12
Not used
Conn 07
1
+24V
DC input
24VDC input. +, 0V and protective earth.
Connector: 3-polar screw terminal, max. conductor
size 2.5mm
2
.
24VDC -5% +20%, .
Power consumption
65W max.
2
0V
3
PE
Conn 08
1
L
AC input
Mains input. Phase, neutral and protective ground.
Connector: 3-polar screw terminal, max. conductor
size 2.5mm
2
.
100-240VAC
50/60Hz.
Power consumption
65W max.
2
N
3
PE
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Содержание Marine Master Clock 70000