9
water solutions
First installation manual – Translation of original instructions
With this type of installation (Fig. 8), the pump can be removed from and replaced in the tank quickly without any work on the system.
System components (Fig. 9):
1a. DAC V coupling device (vertical outlet)
1b. DAC H coupling device (horizontal outlet)
2. Coupling flange or hook (changes depending on pump model)
3. Screws
4. Pipe guides (not included)
5. Spacer bracket
Installation procedure (Fig. 10)
1. Check that the pump is disconnected from the power supply panel and the impeller turns in the correct direction using the procedure described
in point 3.2 “Checking the impeller rotation direction”.
2. Fix the flange to the pump’s outlet port with the screws provided.For models with hooks, fix the hook to the pump body using the screws pro-
vided.
3. Place the coupling device on the bottom of the tank and mark the position of the holes required to fix it.
Fig. 8
2.6 Permitted installation types
Make sure that the atmosphere in the working area is not potentially explosive.
2.6.1 Installation with DAC coupling device
EN
A
B
Fig. 9
3
1a
4
2
5
3
2
1b
Fig. 10
L>5D
90°
D
1
2
3
4
5
6
7
8
Содержание APG GREY Series