background image

7

20-30 degrees.

After making welding seam move the 

electrode back. This is necessary for 

filling the welding crater.

DanGerous factors when 

performinG welDinG 

operations

Fire prevention

• All inflammable materials should be 

removed from the welding area.

• Do not strike the arc on a gas tank or 

near it.

• Never attempt to weld fuel tanks or 

tanks filled with gas unless all measures 

are taken to guarantee that they contain 

no fumes.

• Before welding fuel tanks they must be 

thoroughly cleaned with steam.

Welding fumes

When welding, toxic fumes are emitted. 

Always work in well ventilated areas.

Electric arc light

Always use protecting mask or welding 

helmet, equipped with corresponding 

glass filter. Never use damaged safety 

equipment.

High temperature

Use protective gloves. They provide 

hands protection from ultra-violet light 

and heat, emitted by electric arc. It is 

recommended to wear special clothing.

aDDitional protective 

cloths

When welding with heavy current use 

protecting apron, which will protect you 

from spatter.

When performing overhead welding use 

adequate head wear, which will protect 

your head and neck.

It is recommended to wear closed safety 

boots with steel toe caps.

welDinG seam specifications

Electrode movement is too slow

Very short arc

Very low welding current

Electrode movement is too fast

Very long arc

Very high welding current

Normal seam

maintenance

WARNING! Before disassembling 

any panel of the machine for performing 

any operations inside disconnect the plug 

from the receptacle.

Regularly, depending on usage in dusty 

environment, perform maintenance of 

the machine internals. Remove dust from 

internal components of the machine with 

low pressure air flow.

After maintenance reinstall panels and 

tighten screws.

Never perform welding when the 

machine is open!

troubleshootinG

Before contacting service center 

for technical assistance perform the 

following checks:

• Ensure the welding current regulated by 

potentiometer corresponds the diameter 

and type of the used electrode.

• Power indicator (On) shall not lit when 

there is power failure (check cables, 

outputs, fumes etc.).

• Yellow indicator shows overheating, 

short circuit, too low or too high voltage.

Содержание MMA-200/2

Страница 1: ...Instruction manual Inverter welding machine MMA 200 2 ...

Страница 2: ......

Страница 3: ...o contain long hair 9 Use eye protection Also use face or dust mask if the cutting operation is dusty 10 Connect dust extraction equipment If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used 11 Do not abuse the cord Never carry the tool by the cord or yank it to disconnect it from the receptacle Keep the cord away fro...

Страница 4: ...or Specifications of the welding inverters High speed and welding current adjustment accuracy which provide high welding quality using a welding electrode Welding inverter increases mains frequency from 50 Hz to more than 15 kHz steps down the voltage and generates power direct current for welding by pulse length modulation principle Inverter system also allows reducing size of the transformer and...

Страница 5: ...z Rated power 6 8 kW Current range 20 200 А Operating cycle per 10 min 60 Rated output voltage on the welding arc 28 В No load voltage 67 В Performance 85 Power factor 0 93 Used electrodes 1 6 4 0 mm Protection rating IP21S Insulation class F Net weight 5 1 kg Operating cycle shows the period within which the machine can generate corresponding current It is expressed in based on 10 minutes per cyc...

Страница 6: ...of welding seam Below is the table of admissible current according to diameter of the electrode Electrode diameter mm Welding current А Min Max 1 6 25 50 2 40 80 2 5 60 110 3 2 80 160 4 120 200 Pay attention that depending on the diameter of the electrode higher values of welding current are used for welding in lower position whereas vertical welding or welding in vertical position so called overh...

Страница 7: ...hich will protect you from spatter When performing overhead welding use adequate head wear which will protect your head and neck It is recommended to wear closed safety boots with steel toe caps Welding seam specifications Electrode movement is too slow Very short arc Very low welding current Electrode movement is too fast Very long arc Very high welding current Normal seam Maintenance WARNING Bef...

Страница 8: ...c damage bumps falls etc protect the tool from external sources of heat and chemically active substances as well as liquid and objects penetration provide effective cooling and wastes withdrawal from the tool working zone before disconnecting the tool from the power source turn off the On Off switch WARNING Repair modification and check of ZENIT power tools should be performed only in authorized s...

Страница 9: ...9 ...

Страница 10: ...Demix LLC Head office 14 Shevchenko str 3rd floor Dnepropetrovsk Ukraine 49044 tel fax 38 056 375 43 16 http www en zenit profi com ...

Отзывы: