defrosting pipes.

• To avoid turning over install the 

machine on even surface.

Description

1. Positive socket (+) for connecting 

cable with electrode holder.

2. Negative socket for (-) for connecting 

cable with functional terminal.

3. Potentiometer with a scale. Allows 

adjusting welding current.

4. Thermostatic indicator. Indicator is 

off when the machine operates normally. 

Lit indicator means that temperature 

inside the machine is exceeded and the 

thermic protection has been activated. 

The machine is on but not powered 

until normal temperature is reached. 

After cooling the machine will start 

automatically.

5. Power indicator.

6. «On/Off» switch is on the back panel 

of the welding machine.

technical specifications

Model

MMA-200/2

Rated voltage

220-240 В

Rated frequency

50-60 Hz

Rated power

6.8 kW

Current range

20-200 А

Operating cycle*, % 

per 10 min

60

Rated output voltage 

on the welding arc

28 В

No load voltage

67 В

Performance

85 %

Power factor

0.93

Used electrodes

1.6-4.0 mm

Protection rating

IP21S

Insulation class

F

Net weight

5.1 kg

*Operating cycle: shows the period, 

within which the machine can generate 

corresponding current. It is expressed in 

%, based on 10 minutes per cycle e.g.: 

60% = 6 minutes of operation, 4 minutes 

of waiting etc.).

installation place

Install the machine in such a way so that 

ventilation openings are not obstructed 

(forced circulation). Do not allow 

aggressive steam, dust, humidity etc., 

inside the machine.

Fuse nomi-

nal, A

Welding 

current, A

Receptacle 

capacity, A

Cable sec-

tion, mm

16

130

16

16

20

160

32

16

20

180

32

25

25

200

32

25

Before connecting ensure that voltage, 

indicated on the machine nameplate, 

complies with the voltage and frequency 

of the mains.

connectinG welDinG cables

Any connection to the welding circuit 

Содержание MMA-200/2

Страница 1: ...Instruction manual Inverter welding machine MMA 200 2 ...

Страница 2: ......

Страница 3: ...o contain long hair 9 Use eye protection Also use face or dust mask if the cutting operation is dusty 10 Connect dust extraction equipment If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used 11 Do not abuse the cord Never carry the tool by the cord or yank it to disconnect it from the receptacle Keep the cord away fro...

Страница 4: ...or Specifications of the welding inverters High speed and welding current adjustment accuracy which provide high welding quality using a welding electrode Welding inverter increases mains frequency from 50 Hz to more than 15 kHz steps down the voltage and generates power direct current for welding by pulse length modulation principle Inverter system also allows reducing size of the transformer and...

Страница 5: ...z Rated power 6 8 kW Current range 20 200 А Operating cycle per 10 min 60 Rated output voltage on the welding arc 28 В No load voltage 67 В Performance 85 Power factor 0 93 Used electrodes 1 6 4 0 mm Protection rating IP21S Insulation class F Net weight 5 1 kg Operating cycle shows the period within which the machine can generate corresponding current It is expressed in based on 10 minutes per cyc...

Страница 6: ...of welding seam Below is the table of admissible current according to diameter of the electrode Electrode diameter mm Welding current А Min Max 1 6 25 50 2 40 80 2 5 60 110 3 2 80 160 4 120 200 Pay attention that depending on the diameter of the electrode higher values of welding current are used for welding in lower position whereas vertical welding or welding in vertical position so called overh...

Страница 7: ...hich will protect you from spatter When performing overhead welding use adequate head wear which will protect your head and neck It is recommended to wear closed safety boots with steel toe caps Welding seam specifications Electrode movement is too slow Very short arc Very low welding current Electrode movement is too fast Very long arc Very high welding current Normal seam Maintenance WARNING Bef...

Страница 8: ...c damage bumps falls etc protect the tool from external sources of heat and chemically active substances as well as liquid and objects penetration provide effective cooling and wastes withdrawal from the tool working zone before disconnecting the tool from the power source turn off the On Off switch WARNING Repair modification and check of ZENIT power tools should be performed only in authorized s...

Страница 9: ...9 ...

Страница 10: ...Demix LLC Head office 14 Shevchenko str 3rd floor Dnepropetrovsk Ukraine 49044 tel fax 38 056 375 43 16 http www en zenit profi com ...

Отзывы: