13
6 Load cell check
6.1.1 Press
Function
button, and enter
Other Service
Item, use password 7278. Enter
the
Data Info
interface. There displays the raw data and the convert data, The Raw data is
the original data from the load cell, the convert data is the manual handled data.
To check if the scale is ok or not, remove the tank on the load cell plate. Confirm that
there is nothing on it.
Then check the raw data and the convert data. Normally the data is as below,
Raw data:
2500---2550
Convert data
-15 ---15
6.1.2 If the raw data is incorrect or both data are incorrect, please check the installation
of the load cell; confirm that there is nothing interferential. If problem not resolved, change
load cell or main control board.
6.1.3 If the raw data is ok but the convert dada is no good. That means the scale needs
to be calibrated.
6.1.4 Prepare a sample weight of 10 kg. Press
Function
button, and enter
Other
Service
Item, use password 5814. Enter the
Cal.-scale
interface. Please follow the LCD
display to calibrated the scale.
Содержание AC1000-3G
Страница 1: ...ZELL ZELL MOBILE AIR CON SERVICE SOLUTION Mobile Air Con Service Solution AC1000 3G Service Manual...
Страница 5: ...4 3 Electronic diagram 3 1 Main power diagram 3 2 Main control board diagram...
Страница 6: ...5 4 Flow chart 4 1 Overall layout...
Страница 7: ...6 AC1000 3G BLOCK AND SOLENOID LAYOUT SV9 SV6 SV4 SV5 SV8 SV7 SV2 SV3 SV1...
Страница 8: ...7 4 2General flow chart 4 3 Recovery...
Страница 9: ...8 4 4Purge and drain oil 4 5 Vacuum...
Страница 10: ...9 4 6 PAG oil injection 4 7 Recharge...
Страница 11: ...10 4 8 Pressure up 4 9 Pressure down...