background image

 

 

 

Carl Zeiss 

Copyright 

Primo Star 

 

 
 

B 46-0071 v   03/06 

En
g

lish 

Deutsch 

Fran

ç

ais

Es
p

añol

Р

усский

中文

Knowledge of this manual is required for the operation of the instrument. Would you therefore 

 

please make yourself familiar with the contents of this manual and pay special attention to hints concerning  
safe operation of the instrument. The specifications are subject to change; the manual is not covered  
by an update service. Unless expressly authorized, forwarding and duplication of this document, 

 

as well as utilization and communication of its contents are not permitted. Violations will entail an 

 

obligation to pay compensation. All rights reserved in the event of granting of patents or registration of a utility 
model.  

 

Die Kenntnis dieser Anleitung ist für die Bedienung des Gerätes erforderlich. Bitte machen Sie sich deshalb  
mit dem Inhalt vertraut und befolgen Sie besonders Hinweise, die den sicheren Umgang mit dem Gerät  
betreffen. Änderungen im Interesse der technischen Weiterentwicklung bleiben vorbehalten; das Handbuch  
unterliegt nicht dem Änderungsdienst. Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und 
Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen 

 

verpflichten zu Schadenersatz. Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung 
vorbehalten. 

 

L’utilisation de l'appareil suppose la bonne connaissance du présent mode d’emploi. Nous vous prions par conséquent 
de lire attentivement les informations contenues dans ce document et de respecter notamment les consignes relatives 
à la sécurité d’utilisation. Le fabricant se réserve le droit d’apporter des modifications techniques en fonction de 
l’évolution des technologies. Ces modifications ne sont pas automatiquement prises en compte dans le mode d'emploi 
qui accompagne chaque appareil. Toute divulgation, reproduction ou publication du présent document, même 
partielle, est interdite sans notre autorisation écrite. Toute infraction donne droit au versement de dommages et 
intérêts. Tous les droits sont réservés en cas de délivrance d’un brevet ou de dépôt d’un modèle d'utilité. 

 

El manejo de este equipo presupone el conocimiento de las presentes instrucciones. Por eso le rogamos 
familiarizarse con su contenido y observar en particular las indicaciones que se refieren al manejo seguro del mismo. 
Nos reservamos el derecho a modificaciones en interés del desarrollo técnico; el manual no está sujeto al servicio de 
actualización. Sin nuestro consentimiento expreso no se autoriza ni la entrega y reproducción de este manual, ni el 
aprovechamiento y la comunicación de su contenido. Cualquier contravención implica el pago de una 
indemnización. Reservados todos los derechos para el otorgamiento de patentes o el registro de modelos de 
utilidad. 

 

Знание

 

данной

 

инструкции

 

необходимо

 

для

 

использования

 

прибора

Поэтому

 

необходимо

 

ознакомиться

 

с

 

ее

 

содержанием

 

и

 

особенно

 

следовать

 

указаниям

касающихся

 

безопасного

 

обращения

 

с

 

прибором

Фирма

 

оставляет

 

за

 

собой

 

право

 

на

 

изменения

 

в

 

интересах

 

технического

 

усовершенствования

руководство

 

не

 

подлежит

 

изменениям

Передача

 

и

 

тиражирование

 

данных

 

документов

использование

 

и

 

сообщение

 

их

 

содержания

 

не

 

допускаются

 

без

 

особого

 

разрешения

В

 

случае

 

нарушений

 

полагается

 

возмещение

 

убытков

Фирма

 

оставляет

 

за

 

собой

 

право

 

на

 

выдачу

 

патента

 

или

 

регистрацию

 

зарегистрированной

 

модели

 

版  权 

操作本仪器必须先阅读本手册内容。因此请务必熟悉本手册内容,尤其要遵从有关仪器正确操作的注意事项。技
术可能会有更新,此手册不含升级服务。未经授权禁止复制,利用和转载本手册内容。如有违背必须承担相应赔
偿责任。保留所有申请专利或者样品注册权利。  

 

 
 

Issued by: 

Carl Zeiss MicroImaging GmbH

 

 

 

 

 

P.O.B. 4041, 37030 Göttingen, Germany 

 

Phone: 

+49 (0) 551 5060 660 

 

Fax: 

+49 (0) 551 5060 464 

 E-Mail: 

[email protected] 

 

 

 

www.zeiss.de

 

 

Number of this manual: B 46-0071 v 
Date of issue: Version 7, 03/01/2006 

Содержание Primo Star

Страница 1: ...Primo Star Operating manual Bedienungsanleitung Mode d emploi Instrucciones de manejo...

Страница 2: ...sent mode d emploi Nous vous prions par cons quent de lire attentivement les informations contenues dans ce document et de respecter notamment les consignes relatives la s curit d utilisation Le fabr...

Страница 3: ...ry distance and viewing height 16 3 3 2 Compensating for ametropia and inserting the eyepiece pointer 16 3 3 3 Adjusting transmitted light brightfield on the Full K hler microscope 17 3 3 4 Adjusting...

Страница 4: ...a possible hazard to the instrument or system CAUTION Disconnect the plug in power unit from line power before opening the microscope NOTE This symbol refers you to advice that you must observe under...

Страница 5: ...icroscopes should not be disposed of with household waste dispose of them in compliance with the provisions of the law 1 5 Use The microscope including its original accessories must not be used for mi...

Страница 6: ...by qualified specialists or service staff The operation of the instrument in explosion risk environments is not allowed Make sure to read the safety notes provided with Immersol 518 N immersion oil I...

Страница 7: ...ered Possible defects must be notified to us immediately and steps be taken to minimize damage If notified of such a defect the manufacturer is obligated to rectify it at his discretion either by repa...

Страница 8: ...Carl Zeiss Description Primo Star 8 B 46 0071 v 03 06 English 2 DESCRIPTION 2 1 System overview...

Страница 9: ...Primo Star Description Carl Zeiss B 46 0071 v 03 06 9 English...

Страница 10: ...Plug in power unit 6 Stand 7 ON OFF switch illumination intensity 8 Illumination module 9a Luminous field diaphragm adjustable 9b Luminous field diaphragm fixed 10a Condenser carrier Full K hler 10b...

Страница 11: ...ogen lamp LED illumination or illuminating mirror Integrated fixture for external power supply and cable incl cable with multi standard plug and country specific plug adapters Plastic coated carrying...

Страница 12: ...Phase contrast objective with green inscription and phase stop Ph 2 Objective magnification multiplied by eyepiece magnification results in overall visual magnification e g 10 x 10 100x Numerical aper...

Страница 13: ...specific adapters Fig 3 4 if necessary To this end pull off the attached adapter and plug on the desired adapter Connect the plug in power unit to a power outlet If the plug in power unit cannot be p...

Страница 14: ...Carl Zeiss Start Up and Operation Primo Star 14 B 46 0071 v 03 06 English 3 2 Controls Fig 4 Controls...

Страница 15: ...a Knurled ring for adjustment of luminous field diaphragm with Full K hler equipment only 10b Luminous field diaphragm fixed in Fixed K hler equipment 11a Condenser entering screws in Full K hler equi...

Страница 16: ...Fig 7 3 are equipped with fold over rubber eyecups Fig 7 1 pulled out Fig 7 2 folded over Both eyepieces are suitable for spectacle wearers Additionally they contain a focusing ring for the compensat...

Страница 17: ...the slide by means of the spring lever Fig 4 12 If the microscope stand is equipped with a phase or dark filed slider pull this slider out to the left as far as it will go Turn rotary knob Fig 8 1 on...

Страница 18: ...e Specimen field size and objective aperture change after every objective change Therefore repeat the adjustment of luminous field diaphragm and aperture diaphragm to obtain optimum results 3 3 4 Adju...

Страница 19: ...n Push the slider to the right as far as it will go to move the phase stop into the light path Move the control lever of the aperture diaphragm to fully open it on the Full K hler model or set it to t...

Страница 20: ...4 in the stand Then place the tube horizontally onto the stand In doing so the groove on the underside of the tube must be located above the third holding element Fig 11 3 of the stand Turn the tube...

Страница 21: ...ngers as this will reduce lamp life If the stand is equipped with an LED source replace the complete illumination module including the LED Fig 13 1 Push the illumination module Fig 13 1 or 2 back into...

Страница 22: ...sert Fig 15 1 or Fig 16 3 Push the condenser carrier backward against the spring and inclining it remove it upward from the condenser carrier Fig 15 4 Insert the mirror Fig 16 5 from top through the a...

Страница 23: ...rst install the photo tube Fig 17 7 if necessary refer to Section 3 4 1 Loosen clamp screw Fig 17 8 and remove the dust cap from the photo tube Installing a compact digital camera Sliding mount Fig 17...

Страница 24: ...Loosen grub screw Fig 17 5 Vary the camera lens lens mount distance gradually i e displace the sliding mount with camera on lens mount in defined steps Zoom the camera lens through from wide angle W...

Страница 25: ...owing on it and subsequent wiping it off with a cloth moistened with water to which you may also add a mild detergent Wipe off stubborn oily or fatty dirt immersion oil fingerprints with a cotton bud...

Страница 26: ...jective Low resolving power poor image contrast Dirt or dust on the optical surfaces of objectives eyepieces condenser or filters Clean the respective optical components Greater focus differences afte...

Страница 27: ...ure 5 to 40 C max 75 at 35 C 800 hPa to 1060 hPa Operating data Protection Class Protection Type Electrical safety Pollution degree Overvoltage category Radio interference suppression Line voltage Lin...

Страница 28: ...PL 10x 20 Br foc Specimen stage Dimensions width x depth Stage travel X x Y Coaxial drive Vernier scales Specimen holder Mechanical stage 75x30 right left 140 x 135 mm 75 x 30 mm Optionally right or l...

Отзывы: