Notes on Instrument Safety 

Primo Star 

 

 
 

B 46-0071 v   03/06 

En
g

lish 

 

 

The microscope is equipped with a plug-in power unit allowing line voltages to be used in the 
range between 100 and 240 V ± 10%, 50/60 Hz, without the need for changing the voltage 
setting on the instrument. 
The plug-in power unit meets the requirements of Protection Class II (with protective 
insulation). If its casing is damaged, put the plug-in power unit out of operation. The 
microscope may be operated only with the supplied plug-in power unit. 

 

 

If it is determined that protection measures are no longer effective, the instrument must be 
switched off and safeguarded against inadvertent operation. Please contact a Zeiss service 
agency or the Carl Zeiss Microscopy Service to repair the instrument. 

 

 

 

 

− 

Always disconnect the power cable, before opening the instrument and changing the lamp 
or LED source. 

− 

Wait for the lamp to cool down before replacing it and do not touch the new bulb. 

− 

The instrument may only be opened by qualified specialists or service staff. 

− 

The operation of the instrument in explosion-risk environments is not allowed. 

 

 

Make sure to read the safety notes provided with Immersol 518 N

®

 immersion oil. 

 

 

 

Immersion oil irritates the skin. Avoid any contact with skin, eyes and clothing. 
After skin contact, wash the oil off with plenty of water and soap. 
After eye contact, immediately rinse the eye with plenty of water for at least five minutes.   
If the irritation persists, consult a specialist. 
Proper disposal of immersion oil: Take care to ensure that immersion oil does not enter surface 
water or the sewage system. 

 

 

 

The microscope is not equipped with special devices for the protection from substances that 
are corrosive, potentially infectious, toxic, radioactive, or other substances that could be 
hazardous to health. Make sure to observe all legal regulations, particularly the relevant 
national accident prevention regulations when handling such substances. 

 
 

 

 

− 

Before any transport of the instrument, switch it off and let it cool down (hot surface at the 
bottom of the instrument). 

− 

Operate the device only on a hard, non-combustible support. 

− 

The plug-in power unit must not get in contact with moisture. 

 

Содержание Primo Star

Страница 1: ...Primo Star Operating manual Bedienungsanleitung Mode d emploi Instrucciones de manejo...

Страница 2: ...sent mode d emploi Nous vous prions par cons quent de lire attentivement les informations contenues dans ce document et de respecter notamment les consignes relatives la s curit d utilisation Le fabr...

Страница 3: ...ry distance and viewing height 16 3 3 2 Compensating for ametropia and inserting the eyepiece pointer 16 3 3 3 Adjusting transmitted light brightfield on the Full K hler microscope 17 3 3 4 Adjusting...

Страница 4: ...a possible hazard to the instrument or system CAUTION Disconnect the plug in power unit from line power before opening the microscope NOTE This symbol refers you to advice that you must observe under...

Страница 5: ...icroscopes should not be disposed of with household waste dispose of them in compliance with the provisions of the law 1 5 Use The microscope including its original accessories must not be used for mi...

Страница 6: ...by qualified specialists or service staff The operation of the instrument in explosion risk environments is not allowed Make sure to read the safety notes provided with Immersol 518 N immersion oil I...

Страница 7: ...ered Possible defects must be notified to us immediately and steps be taken to minimize damage If notified of such a defect the manufacturer is obligated to rectify it at his discretion either by repa...

Страница 8: ...Carl Zeiss Description Primo Star 8 B 46 0071 v 03 06 English 2 DESCRIPTION 2 1 System overview...

Страница 9: ...Primo Star Description Carl Zeiss B 46 0071 v 03 06 9 English...

Страница 10: ...Plug in power unit 6 Stand 7 ON OFF switch illumination intensity 8 Illumination module 9a Luminous field diaphragm adjustable 9b Luminous field diaphragm fixed 10a Condenser carrier Full K hler 10b...

Страница 11: ...ogen lamp LED illumination or illuminating mirror Integrated fixture for external power supply and cable incl cable with multi standard plug and country specific plug adapters Plastic coated carrying...

Страница 12: ...Phase contrast objective with green inscription and phase stop Ph 2 Objective magnification multiplied by eyepiece magnification results in overall visual magnification e g 10 x 10 100x Numerical aper...

Страница 13: ...specific adapters Fig 3 4 if necessary To this end pull off the attached adapter and plug on the desired adapter Connect the plug in power unit to a power outlet If the plug in power unit cannot be p...

Страница 14: ...Carl Zeiss Start Up and Operation Primo Star 14 B 46 0071 v 03 06 English 3 2 Controls Fig 4 Controls...

Страница 15: ...a Knurled ring for adjustment of luminous field diaphragm with Full K hler equipment only 10b Luminous field diaphragm fixed in Fixed K hler equipment 11a Condenser entering screws in Full K hler equi...

Страница 16: ...Fig 7 3 are equipped with fold over rubber eyecups Fig 7 1 pulled out Fig 7 2 folded over Both eyepieces are suitable for spectacle wearers Additionally they contain a focusing ring for the compensat...

Страница 17: ...the slide by means of the spring lever Fig 4 12 If the microscope stand is equipped with a phase or dark filed slider pull this slider out to the left as far as it will go Turn rotary knob Fig 8 1 on...

Страница 18: ...e Specimen field size and objective aperture change after every objective change Therefore repeat the adjustment of luminous field diaphragm and aperture diaphragm to obtain optimum results 3 3 4 Adju...

Страница 19: ...n Push the slider to the right as far as it will go to move the phase stop into the light path Move the control lever of the aperture diaphragm to fully open it on the Full K hler model or set it to t...

Страница 20: ...4 in the stand Then place the tube horizontally onto the stand In doing so the groove on the underside of the tube must be located above the third holding element Fig 11 3 of the stand Turn the tube...

Страница 21: ...ngers as this will reduce lamp life If the stand is equipped with an LED source replace the complete illumination module including the LED Fig 13 1 Push the illumination module Fig 13 1 or 2 back into...

Страница 22: ...sert Fig 15 1 or Fig 16 3 Push the condenser carrier backward against the spring and inclining it remove it upward from the condenser carrier Fig 15 4 Insert the mirror Fig 16 5 from top through the a...

Страница 23: ...rst install the photo tube Fig 17 7 if necessary refer to Section 3 4 1 Loosen clamp screw Fig 17 8 and remove the dust cap from the photo tube Installing a compact digital camera Sliding mount Fig 17...

Страница 24: ...Loosen grub screw Fig 17 5 Vary the camera lens lens mount distance gradually i e displace the sliding mount with camera on lens mount in defined steps Zoom the camera lens through from wide angle W...

Страница 25: ...owing on it and subsequent wiping it off with a cloth moistened with water to which you may also add a mild detergent Wipe off stubborn oily or fatty dirt immersion oil fingerprints with a cotton bud...

Страница 26: ...jective Low resolving power poor image contrast Dirt or dust on the optical surfaces of objectives eyepieces condenser or filters Clean the respective optical components Greater focus differences afte...

Страница 27: ...ure 5 to 40 C max 75 at 35 C 800 hPa to 1060 hPa Operating data Protection Class Protection Type Electrical safety Pollution degree Overvoltage category Radio interference suppression Line voltage Lin...

Страница 28: ...PL 10x 20 Br foc Specimen stage Dimensions width x depth Stage travel X x Y Coaxial drive Vernier scales Specimen holder Mechanical stage 75x30 right left 140 x 135 mm 75 x 30 mm Optionally right or l...

Отзывы: