![Zeiss Axiotech Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/zeiss/axiotech/axiotech_operating-manual_3383120030.webp)
Carl Zeiss
Axiotech and Axiotech
vario
1-16
B 40-020 e 06/99
1.8
Microscope stages and specimen holders
The microscopes in the Axiotech line can be equipped with the following microscope stages and
specimen holders:
Description
Cat. No.
Notes
Reflected-light mechanical stage
75
×
50 R
453527-0000-000
contained in the delivery package of the
Axiotech 30 and Axiotech 100 microscopes,
stage carrier A also required for Axiotech
Mechanical stage 75
×
50/240° R
000000-1046-626
optional:
−
specimen holder A for reflected light
−
specimen holder with spring clip R,
−
Universal mounting frame P
Mechanical stage 75
×
50 R with low-
mounted stage drive and ceramic
surface
453522-9901-000
optional:
−
specimen holder A for reflected light
−
specimen holder with spring clip R
Mechanical stage 75
×
50 mot with
control unit
000000-1025-145
optional with joystick for 2 axes or
coaxial electronic drive
Rotary stage Pol with stage carrier
453556-0000-000
optional:
Pol specimen holder
Gliding stage
453509-0000-000
only for reflected light
Stage carrier H = 140 mm
000000-1056-656
only for Axiotech
vario
Universal mounting frame P
453545-0000-000
optional for mechanical stage 75
×
50/240° R
Specimen holder with spring clip R
453533-0000-000
optional for mechanical stage 75
×
50/240° R
Specimen holder A for reflected light
453539-0000-000
optional for mechanical stage 75
×
50/240° R
Specimen holder with spring clip R
473448-0000-000
optional for mechanical stage 75
×
30 R
Specimen holder A for reflected light
433411-0000-000
optional for mechanical stage 75
×
30 R
Specimen holder Pol
473325-0000-000
can be attached to Pol rotary stage
☞
The rotary stage Pol and the gliding stage are both supplied with a factory-attached stage
carrier. If these microscope stages are used with the Axiotech
vario
100, the stage carrier must be
removed and the stage screwed onto the stage carrier H = 140 mm. This, however, results in
the loss of the factory-set centering of the Pol rotary stage, i.e. the subsequent centering of the
microscope stage might be necessary (also see section 2.8.4).
Содержание Axiotech
Страница 1: ...Axiotech and Axiotechvario Materials Microscopes Operating Manual...
Страница 14: ...Carl Zeiss Axiotech and Axiotechvario XIV B 40 020 e 06 99...
Страница 16: ...Carl Zeiss Axiotech and Axiotechvario 1 2 B 40 020 e 06 99...
Страница 20: ...Carl Zeiss Axiotech and Axiotechvario 1 6 B 40 020 e 06 99 Fig 1 2 Microscope components and modules sheet 2...
Страница 112: ...Carl Zeiss Axiotech and Axiotechvario 3 46 B 40 020 e 06 99...
Страница 114: ...Carl Zeiss Axiotech and Axiotechvario 4 2 B 40 020 e 06 99...
Страница 124: ...Carl Zeiss Axiotech and Axiotechvario A 2 B 40 020 e 06 99...